beautypg.com

Tripp Lite H2561 User Manual

Page 5

background image

5

© 2008 TRIPP LITE. ALL RIGHTS RESERVED. THE POLICY OF TRIPP LITE IS ONE OF CONTINUOUS IMPROVEMENT.

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

ALL TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS.

Single Power Supply, or Multiple Power Supplies Operating in Redundant Mode

Configuration

1

2

3

4

5

Power Supply

PS1

PS1

PS2

PS1

PS2

PS1 & PS2

PS1

PS2

Power Source

Wall

Wall

Wall

UPS1

Wall

UPS1

UPS1

UPS2

PS1 Status

Utility Status

UPS Status

System Status System Status

System Status

System Status

System Status

OK

OK

OK

OK

OK

OK

OK

OK

Failure

OK

OK

Crash

OK

OK

Crash

OK

OK

Blackout

OK

Crash

Crash

OK

OK

OK

OK

Blackout

UPS1 Battery

Crash

Crash

Crash

Crash

OK

Fails

OK

Blackout

UPS1 Internal

Crash

Crash

Crash

Crash

OK

Fault

OK

OK

UPS1 Battery

OK

OK

OK

Fails

Hot swap battery

Hot swap battery

Hot swap battery

OK

OK

UPS1 Internal

OK

Crash

OK

Fault

Replace UPS.

Replace UPS.

Replace UPS.

System on PS2/Wall.

System on PS2/UPS2.

Vulnerable to outage

Services OK during

during UPS

UPS replacement

replacement

OK

OK

OK

UPS on bypass,

UPS on bypass.

UPS on bypass,

System on PS2/Wall.

System on Wall.

System on PS2/UPS2.

Replace UPS1.

Services down*

Replace UPS1.

Vulnerable to

while replacing

Services OK during

outage during UPS

UPS1

UPS replacement

replacement

*SmartOnline Hot-Swappable Modular 5-16KVA UPS system hardware can be hot swapped without service outage.

Line-Interactive UPS Systems

On-Line UPS Systems

STEP 1: Determine Configuration

STEP 2: Consider Failure Scenarios

STEP 3: Consider System Status

STEP 2: Consider Failure Scenarios

STEP 3: Consider System Status

Multiple Power Supplies Operating in Dual (Combined, Non-Redundant) Mode

Configuration

1

2

3

Power Supply

PS1

PS2

PS1

PS2

PS1

PS2

Power Source

Wall

Wall

UPS1

UPS1

UPS2

PS1 Status

Utility Status

UPS Status

System Status

System Status

System Status

OK

OK

OK

OK

OK

OK

Failure

OK

OK

Reduced Output

OK

OK

OK

Blackout

OK

Crash

OK

OK

OK

Blackout

UPS1 Battery

Crash

Crash

Reduced Output

Fails

Replace UPS1.

Replace UPS1.

Output reduced during UPS

Output reduced during UPS

replacement

replacement

OK

Blackout

UPS1 Internal

Crash

Reduced Output

Fault

Replace UPS1

Replace UPS1. Output reduced

until UPS1 replacement

OK

OK

UPS1 Battery

OK

OK

Fails

Hot swap battery

Hot swap battery

OK

OK

UPS1 Internal

Crash

Reduced Output

Fault

Replace UPS. Plug into wall until

Replace UPS1. Plug PS1 into wall

UPS replacement

to restore full power until UPS1

replacement. Output reduced

until UPS1 replacement

OK

OK

Replace UPS1.

Replace UPS1.

Both PS on UPS Bypass.

PS1 on UPS1 Bypass circuit,

Services down* while replacing

vulnerable to outage. Reduced

UPS1

power during UPS1 replacement

*SmartOnline Hot-Swappable Modular 5-16KVA UPS system hardware can be hot swapped without service outage.

STEP 1: Determine Configuration

Line-Interactive UPS Systems

On-Line UPS Systems

This manual is related to the following products: