G100, Power flow-thru humidifier, G 100 – Trion G100 User Manual
Page 2: Installation options evaporative supply capacity, Humidifier capacity selection guide

w w w. t r i o n i n c . c o m
G100
Power Flow-Thru Humidifier
©2008 Trion
®
- Indoor Air Quality Solutions | Herrmidifier
®
- Engineered Humidification Solutions Trion
®
and Herrmidifier
®
are registered trademarks
of Air System Components, Inc. Trion
®
reserves the right to revise or modify products and/or specifications without notice
.
All product specifications reflect available information at the printing of this brochure.
Trion
®
| 101 McNeill Road | Sanford, NC 27330 | Phone: 800 884-0002 | Fax: 800-458-2379
Web: www.trioninc.com | Email: [email protected]
Form No. H-G100-1008
T E C H N I C A L E N G I N E E R I N G S P E C I F I C A T I O N
A i r P u r i f i c a t i o n S y s t e m s
Upflow Bottom Return
Downflow Counterflow
Upflow Side Return
Horizontal
Model
G100
PART NO.
351453-001
TYPE OF UNIT
Power-Assisted Flow-Thru
VOLTAGE/HZ/MOTOR
120 / 60 / 1/20 hp (0.037 KW)
SOLENOID VALVE
24 V Brass, rated for 150 psi (10.34 bar)
EVAPORATOR PAD
G-116-6 (6 pack only)
EVAPORATOR PAD SIZE 9” W x 2” D x 14” H (229 x 51 x 356 mm)
WEIGHT
13 lbs. (5.9 kg) / Shipping – 18 lbs. (8.16 kg)
DIMENSIONS
Unit – 13” W x 11 1/2” D x 18 3/4” H (330 x 292 x 476 mm)
Packaging – 21 5/8” W x 16 5/8” D x 151/4” H (549 x 422 x 387 mm)
DUCT OPENING
12 1/4” W x 15 1/2” H (311 x 394 mm)
HUMIDISTAT
Adjustable from 20% to 80% Relative Humidity
DRAIN TUBING
1/2” (12.8 mm) O.D.
G 100
1. A “Tight Home” is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a
dampered fireplace. Air exchange rate of .5 changes per hour.
2. An “Average Home” is insulated and has a dampered fire place, but there are no vapor barriers, storm doors,
or storm windows. Air exchange rate of 1.0 change per hour.
3. A “Loose Home” is generally one constructed before 1930, has little or no insulation, no storm doors, storm
windows, weather stripping or vapor barriers, and often no effective dampering of fireplaces. Air exchange rate
is as high as 1.5 changes per hour.
Installation Options
Evaporative Supply Capacity
Furnace Temp.
Supply Side
°F
°C
Gallons per Day
Liters per Hour
100°F
37.7°C
14.5
(2.3)
120°F
48.8°C
19.0
(3.0)
140°F
60°C
24.0
(3.8)
Sq. Ft.
Meters of
Home
Tight
1
House
Average
2
House
Loose
3
House
1000
(92.9 m2
0.5
(1.9)
5.0
(18.9)
10.0
(37.9)
1500
(139.4 m2)
3.0
(11.4)
10.0
(37.9)
16.5
(62.5)
2000
(185.8 m2)
5.0
(18.9)
14.0
(52.9)
24.0
(90.8)
2500
(232.3 m2)
7.5
(28.4)
19.0
(71.9)
30.5
(115.5)
3000
(278.7 m2)
10.0
(37.9)
23.5
(88.9)
37.5
(141.9)
3500
(325.2 m2)
14.5
(54.9)
33.0
(124.9)
51.5
(194.9)
Humidifier Capacity Selection Guide