T E C H N I C A L E N G I N E E R I N G S P E C I F I C A T I O N

A i r P u r i f i c a t i o n S y s t e m s

Upflow Bottom Return

Downflow Counterflow

Upflow Side Return

Horizontal

Model

G100

PART NO.

351453-001

TYPE OF UNIT

Power-Assisted Flow-Thru

VOLTAGE/HZ/MOTOR

120 / 60 / 1/20 hp (0.037 KW)

SOLENOID VALVE

24 V Brass, rated for 150 psi (10.34 bar)

EVAPORATOR PAD

G-116-6 (6 pack only)

EVAPORATOR PAD SIZE 9” W x 2” D x 14” H (229 x 51 x 356 mm)
WEIGHT

13 lbs. (5.9 kg) / Shipping – 18 lbs. (8.16 kg)

DIMENSIONS

Unit – 13” W x 11 1/2” D x 18 3/4” H (330 x 292 x 476 mm)
Packaging – 21 5/8” W x 16 5/8” D x 151/4” H (549 x 422 x 387 mm)

DUCT OPENING

12 1/4” W x 15 1/2” H (311 x 394 mm)

HUMIDISTAT

Adjustable from 20% to 80% Relative Humidity

DRAIN TUBING

1/2” (12.8 mm) O.D.

G 100

1. A “Tight Home” is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a

dampered fireplace. Air exchange rate of .5 changes per hour.

2. An “Average Home” is insulated and has a dampered fire place, but there are no vapor barriers, storm doors,

or storm windows. Air exchange rate of 1.0 change per hour.

3. A “Loose Home” is generally one constructed before 1930, has little or no insulation, no storm doors, storm

windows, weather stripping or vapor barriers, and often no effective dampering of fireplaces. Air exchange rate

is as high as 1.5 changes per hour.

Installation Options

Evaporative Supply Capacity

Furnace Temp.

Supply Side

°F

°C

Gallons per Day

Liters per Hour

100°F

37.7°C

14.5

(2.3)

120°F

48.8°C

19.0

(3.0)

140°F

60°C

24.0

(3.8)

Sq. Ft.

Meters of

Home

Tight

1

House

Average

2

House

Loose

3

House

1000

(92.9 m2

0.5

(1.9)

5.0

(18.9)

10.0

(37.9)

1500

(139.4 m2)

3.0

(11.4)

10.0

(37.9)

16.5

(62.5)

2000

(185.8 m2)

5.0

(18.9)

14.0

(52.9)

24.0

(90.8)

2500

(232.3 m2)

7.5

(28.4)

19.0

(71.9)

30.5

(115.5)

3000

(278.7 m2)

10.0

(37.9)

23.5

(88.9)

37.5

(141.9)

3500

(325.2 m2)

14.5

(54.9)

33.0

(124.9)

51.5

(194.9)

Humidifier Capacity Selection Guide