beautypg.com

Framing specifications – TOA Electronics CUSTOM SERIES RD-36 User Manual

Page 7

background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

7

Figure 15

Figure 16

Figure 14

Framing Dimensions

A

43"

1092 mm

B

44

¹⁄₂"

1130 mm

C

29

¹⁄₂"

749 mm

D

15

³⁄₄"

400 mm

E

73"

1854 mm

F

36

¹⁄₂"

927 mm

G

21

³⁄₄"

552 mm

H

20

³⁄₄"

527 mm

J

51

⁵⁄₈"

1311 mm

Framing Dimensions for Roof

Pitch

C

D*

0/12

16

¹⁄₂"

16

¹⁄₂"

(419 mm)

(419 mm)

6/12

16

¹⁄₂"

19"

(419 mm)

(483 mm)

12/12

16

¹⁄₂"

23

¹⁄₂"

(419 mm)

(597 mm)

Framing Dimensions for Ceiling

Flue Type

A

B

FTF8 Vertical

16

¹⁄₂"

16

¹⁄₂"

(419 mm)

(419 mm)

FTF8 Offset 30

°

16

¹⁄₂"

25"

(419 mm)

(635 mm)

Note: All framing dimensions calcu-
lated for 1/2" dry wall at the fireplace
face. If sheathing the chase or finish-
ing with other thickness materials,
calculations will need to be made.

* Perpendicular to roof ridge

A

B

Ceiling Framing

C

D

Roof Framing

FRAMING SPECIFICATIONS

Figure 11

Figure 12

Figure 13

A

G

Inside Chase

H

Back Wall of Chase/Enclosure

Including Finising Materials if any

Rough

Framing Face

(Unfinished Shown)

FOAK Combustion

Air Kit

A

Outside Chase

G

C

H

Back Wall of Chase/Enclosure

Including Finising Materials

if any

Rough

Framing Face

(Unfinished Shown)

FOAK

Combustion

Air Kit - Optional

Corner Installation

J

D

A

E

F

Back Wall of

Chase/Enclosure

Including Finising

Materials

if any

Rough
Framing Face
(Unfinished Shown)

FOAK Combustion

Air Kit - Optional

Header

Fireplace Framing

B

A

Note: When Framing With 6” Studs Header Must
Be 17” (432mm) Higher. Use Security’s OR15
Offset/Return Elbow To Recess The Chimney Back
2 1/2” (64mm). Maintain Required Clearance To
Chimney At All Times.