Toshiba SR-C8002 User Manual
Page 9

4/24
SR-C8002 Rev.1.0
(10) Drawer Load/Release Load:
Manual
Release:
(a) Electrical Release (Release Button)
(b) Release by ATAPI command
(c) Emergency Release
(11) Air Flow
Not Required
(12) Acoustic Noise
40 dB (IEC 179 A weighted at 1 m)
(13) Power Supply
+5 V (details in Section 7)
3.2. Environmental Conditions
This drive should be used under the conditions listed below.
3.2.1.Temperature and Humidity
(1) Operating Temperature
5
°
C
to 50
°
C
*1
(2) Storage Temperature
-10
°
C
to 60
°
C
(3) Shipping Temperature
-40
°
C
to 65
°
C
*2
(4) Operating Temperature Gradient
11
°
C
/hour (max)
(5) Storage Temperature Gradient
20
°
C
/hour (max)
(6) Shipping Temperature Gradient
20
°
C
/hour (max) *2
(7) Operating Humidity
8 % to 80 %
(8) Storage Humidity
5 % to 95 %
(9) Shipping Humidity
5 % to 95 % *2
(10) Wet bulb Maximum Temperature
27
°
C
(11) Condensation
In all the above conditions there must be no condensation
*1: Except for disc
*2: Packed in Toshiba original shipping package.
3.2.2.Dust and Dirt
unspecified