Surround installations, Figure 13 figure 14 – TOA Electronics VF5000-CMP-2 User Manual
Page 8
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
8
Surround Installations
Note: The VF5000/VF6000 series appliances
must be installed giving full consideration to
the clearance and height requirements identi-
fied in this manual.
Figure 15
White
(Supply)
Black
(Supply)
Bipolar
Terminal
Screw
Blower
(Lower)
Outlet
Black
Wire
Mating
Connectors
Red Wire
120 Vac
60 Hz
Blower Wiring Diagram
}
OFF/ON Blower
Wall Switch
To Fuse or
Circuit Breaker
120V
AC
60Hz
Fireplace
Junction Box
Black
White
Receptacle
Ground Wire
Connection
Note: Supply wires may be alternatively connected to the outlet using the screw terminals,
however the black supply wire must be ganged wired to the same terminal that the pre-wired black
wire is attached to and the white supply wire must be connected to the opposite side of the outlet.
IMPORTANT: Ground lead must be connected
to the green screw located on the junction box
cover plate. Failure to do so will prevent the
appliance from operating. The appliance must
be electrically grounded in accordance with
local codes or, in the absence of local codes, the
National Electrical Code, ANSI/NFPA 70-(latest
edition). (In Canada, the current CSA C22-1
Canadian Electrical Code.)
The forced air blower kit may be mounted at
initial appliance installation or at any time there-
after. Follow the instructions provided with the
blower kit.
Finished Wall Details
It is sometimes best to frame the appliance
after it has been positioned in place. Frame with
2 x 4s or heavier lumber. Always frame in
accordance with local building codes.
Note: The header may rest on the top spacers
but must not be notched to fit around them.
In order to install the appliance facing flush with
the finished wall, position the framework to
accommodate the thickness of the finished wall
(
Refer to Figures 2 and 3 ).
If you live in a cold climate, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter the
room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level.
Proceed to Step 12.
Figure 16
VF5000/VF6000 Series
Standard Wiring Diagram
TPTH
TP
TH
Thermopile
If any of the original wire as supplied must be replaced, it
must be replaced with
Type AWM 105°C – 18 GA. wire.
* For Rocker or ON/OFF Wall Switch Attachment Only.
*
*
From Thermocouple
VF5000/VF6000 Series
Optional Wiring Diagram
TPTH
TP
TH
Thermopile
If any of the original wire as supplied must be replaced, it
must be replaced with
Type AWM 105°C – 18 GA. wire.
Optional ON/OFF
Wall Switch/Rocker Switch
Factory Wired
Field Wired
*
* For Rocker Switch Attachment Only.
*
From Thermocouple
Figure 13
Figure 14