SISTF10xx-130-LR(T)

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Technical Specifications

For use with Transition Networks Model SISTF10xx-130-LR(T) or equivalent

Standards:

IEEE 802.3™, 802.3u™; 802.3x™

Data Rate:

10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber)

Processing Type:

Store and Forward
w/ IEEE802.3x™ full-duplex, non-blocking flow control

Dimensions:

1.8" x 5.3" x 4.1" (46 mm x 135 mm x 105 mm)

Weight:

1.4 lb. (0.65 kg) (approximate)

Input Power:

12-48VDC, 0.2-0.7A, 24W (minimum), (redundant inputs)
with overload and reverse polarity protection

Address Table Size: 1,000 Unicast Mac addresses

Alarm Relay:

1 Amp @ 24 VDC

Mechanical:

Ingress Protection: IP30

Environment:

Tmra* (standard temp): 0 to 60°C (32 to 140°F)
Tmra* (extended temp): -40 to 75°C (-40 to 167°F)

Storage Temperature:

-40 to 85°C (-40 to 185°F)

Humidity:

5 to 95%, non condensing

Warranty:

Lifetime

*Manufacturer’s rated ambient temperature.

The information contained in this user’s guide is subject to change. For the most
up-to-date information see the user’s guide on line at: www.transition.com.

This device is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION: Visible and invisible laser radiation when open. Do not
stare into beam or view directly with optical instruments.

CAUTION: Use of controls, adjustments or the performance of
procedures other than those specified herein may result in hazardous
radiation exposure

CAUTION: This device is intended to be supplied by a listed power unit
marked LPS or Limited Power Source, provided with a connector for field
wiring terminal, and output rated 12-48VDC, 0.2-0.7 A, 24 W minimum.

CAUTION: This device is designed for operation with a safety extra-low
voltage (SELV) in compliance with IEC950 / EN60950 / VDE0805 and in
compliance with the low voltage directive 73/23/EEC and 93/68/EEC.

[email protected] -- Click the “Transition Now” link for a live Web chat.

13

Test

Description

Test Levels

IEC 60068-2-6

Vibration

10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes)

IEC 60068-2-27

Shock

50 g, 11 ms, +/-X, +/-Y, +/- Z (6 direction)

IEC 60068-2-32

Free fall

75 cm, 1 corner, 3 edges, 6 faces (total 10 drops)

Environmental Type Tests

Test

Description

Test Levels

Severity

IEC61000-4-2 ESD

Air discharge

+/- 8 KV

3

Contact discharge

+/- 6 KV

3

ESD contact discharge

+/- 6 KV

3

IEC61000-4-3 Radiated RFI

Housing

10V/m, 80 MHz - 1 GHz
AM 1 KHz, 80% mod
10 V/m, 0.9 - 1.8 GHz
FM 200 Hz 50% square

3

IEC61000-4-4 Burst

(Fast Transient)

Power supply lines

+/- 2 KV

3

Communication lines

+/- 1 KV

3

Relay

+/- 1 KV

3

IEC61000-4-5 Surge

Power supply lines

+/- 2 KV, 12

Ω, CM

+/- 1 KV, 2

Ω, DM

3

Relay

+/- 2 KV, 12

Ω, CM

+/- 1 KV, 2

Ω, DM

3

IEC61000-4-6 Induced

(Conducted RFI)

Power supply lines

10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod

3

Communication lines

10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod

3

Relay

10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod

3

Technical Specifications

-- Continued

EMS Type Tests