7

If you require the voltage setting to be
altered, e.g. relocation to another area, city or
country, or extraordinarily high or low
voltages, contact your Perreaux dealer. This
modification must only be performed by
qualified service personnel.

Note: Always ensure the unit is disconnected
from the Mains/Line supply before any covers
are removed.

MAINS/LINE FUSE


The Perreaux 200P is equipped with a user
serviceable mains/line fuse. Above the
mains/line cord is the mains/line fuse holder.
In the unlikely event of fuse failure always
replace with the same type and value fuse.
Remember, fuses do not usually blow without
a reason. Any doubts about fuse failure
should be conveyed directly to your Perreaux
dealer.

The fuse ratings are:

100-125V 2SB SLOW BLOW 8A
Continuous
200-250V 2SB SLOW BLOW 6A
Continuous
Note: Always ensure your 200P is
disconnected from the Mains/Line supply
before attempting to change the Mains/Line
fuse.


RAIL FUSES


The Perreaux 200P has 4 internal fuses for
amplifier protection. In the unlikely event of
internal fuse failure consult your Perreaux
dealer. The internal fuses are not user
serviceable
and only authorised personnel
may replace the internal fuses.


Fuse Rating -3AG Normal Acting 6 Amp

SERIAL NUMBER


All Perreaux units are allocated a unique
serial number which are recorded at the
factory against build details. If you should
require information about your unit, providing
the serial number will help achieve a prompt
reply.Keep a copy of all your serial numbers
in a safe place. The ability to identify and
prove ownership can be very useful.


SPECIFICATIONS

Tested at 120 / 220 / 230 / 240V ac
mains voltage after initial 10 minute warm
up period

POWER

OUTPUT

200 watts RMS per channel continuous
both channels driven into 8

from 20Hz

to 20kHz at no more than 0.02% THD


300 watts RMS into 4

FREQUENCY

RESPONSE

±

0.25dB from 20Hz to 20kHz


TOTAL HARMONIC DISTORTION

0.02% THD worst case prior to clipping

0.004% THD @ 1KHz


HUM,

NOISE

-95dB unweighted referenced to rated
output


INPUT

SENSITIVITY

Balanced 0.6V

RMS

Unbalanced 1.2V RMS


INPUT

IMPEDANCE

Balanced

3.3k

Unbalanced

22k


DYNAMIC

HEADROOM

1.9dB
CURRENT

OUTPUT

24 Amperes peak per channel


DRIVER

STAGE

Class

A


OUTPUT

STAGE

Class A / AB

DIMENSIONS (not including handles and
terminals)


HEIGHT x WIDTH x DEPTH

88mm x 482mm x 460mm

3.5" x 19.0" x 18.1"


NETT

WEIGHT

17.0kg