beautypg.com

TOA Electronics P0055-DRG User Manual

Page 4

background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

CAUTION: DO NOT ATTEMPT TO TOUCH THE
DOORS WITH YOUR HANDS WHILE THE FIRE-
PLACE IS IN USE. ALWAYS USE DOOR
HANDLES. DOORS WILL BECOME VERY HOT
WHEN FIREPLACE IS IN USE.

Figure 4

Figure 3

2. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due
to excessive lint from carpeting, bedding ma-
terials, etc. It is important that control com-
partments, burners and circulating air pas-
sageways of the appliance be kept clean.

3. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-lighting,
refer to the lighting instructions in this manual.
Appliance lighting instructions may also be
found on the pull-out label located near the
gas valve in the control compartment.

4. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.

5. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution
when using products with combustible vapors.

6. Clean the optional glass doors only when
necessary. Wipe surface with clean, damp-
ened, soft cloth. Follow with dry, soft towel as
desired. Take care not to scratch the glass
surface.

Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operating your appliance determine if you have
a millivolt or electronic appliance. Millivolt
appliances will be fitted with the gas control
valve shown in

Figure 3. Appliances with

electronic systems will be fitted with the elec-
tronic valve shown in

Figure 4. Familiarize

yourself with the differing controls for the
valve your appliance uses.

Millivolt Appliance Lighting
To light millivolt appliances refer to the de-
tailed lighting instructions found in both En-
glish and French on

pages 10 and 11 of these

instructions respectively. Appliance lighting
instructions may also be found on the pull-
out label located near the gas valve in the
control compartment.
Refer to

Figure 1 for

the piezo ignitor location used with your
appliance.

Your appliance comes supplied with remote
wall switch or can be used with an optional
remote control kit. The appliance main burner
may be turned on and off with the wall switch
or remote control.

Electronic Appliance Lighting
To light electronic appliances refer to the de-
tailed lighting instructions found in both En-
glish and French on

pages 12 and 13 of these

instructions respectively. Appliance lighting
instructions may also be found on the pull-
out label located near the gas valve in the
control compartment.

Your appliance comes supplied with remote
wall switch or can be used with an optional
remote control kit. The appliance main burner
may be turned on and off with the wall switch
or remote control.

1. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is
due to the “burn-in” of internal paints and
lubricants used in the manufacturing process.

WARNING: FIREPLACES EQUIPPED
WITH OPTIONAL ACCESSORY DOORS
SHOULD BE OPERATED ONLY WITH THE
DOORS FULLY OPEN OR FULLY CLOSED
(FIGURE 5 )
. THIS APPLIANCE MAY
ONLY BE FITTED WITH DOORS CERTI-
FIED FOR USE WITH THE APPLIANCE.

Appliances may be installed with an outside
(make-up air) vent system that is designed to
provide the appliance with outside make-up
air for combustion when in operation. The
shut-off lever for the outside air system is
standard on all appliances but should not be
operated if the complete system is not in-
stalled. Refer to

Figure 6 for GHC/GRD-5500

series units.

The hand operated shut-off lever is located in the
left side of the fireplace opening behind the
screen. To open, pull all the way. The outside air
damper should be fully open when the fireplace
is in use and completely closed when the fire-
place is not being used. This will prevent outside
cold air from entering the dwelling.

Figure 5

Outside Combustion Air Controls

Combustion Air Control Lever

on GHC/GRD-5500 Series Units

Figure 6

WARNING: DO NOT OPERATE THE
SHUTOFF LEVER UNLESS A COMPLETE
OUTSIDE AIR VENT SYSTEM HAS BEEN
INSTALLED WITH YOUR APPLIANCE.

WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.

AVERTISSEMENT: POUR UTILISATION
UNIQUEMENT AVEC LES PORTES EN
VERRE CERTIFIÊES AVEC L'APPAREIL.

CONTROL KNOB

MILLIVOLT GAS CONTROL VALVE

M

C

P

O

N

O

F

F

ON/OFF SWITCH

ELECTRONIC GAS CONTROL VALVE

Glass Doors

Fully Open or

Fully Closed

(Bi-Fold Doors)

Combustion Air Control Lever