beautypg.com

User’s information, Set-up mode, Factory settings – Trane CleanEffects Air Filtration System User Manual

Page 5: Fig. 3 pre-filter timer setting, Collection cell timer setting, Field charger power level setting

background image

32-5035-02

5

User’s Information

SET-UP MODE

You can customize the performance of the air
cleaner to meet the needs of your home and

family using the set-up mode.

To enter the set-up mode, press and hold
BOTH the Power and the filter RESET buttons
for a minimum of 5 seconds. The LED display
will light up indicating the current settings as

shown in Figure 3 to the right.

You may select the cleaning intervals of the
pre-filter and the collection cells as well as the
power setting of the field charger by cycling
through the various settings (see page 6).
Once you have made the desired changes,
press and hold BOTH the Power and the filter
RESET buttons for a minimum of 5 seconds to

exit the set-up mode.

G1

G2

G3

Y1

Y3

Y4

R1

R2

R3

Y2

CLEAN

DIRTY

Factory settings

Field Charger Power

Maximum

Collection Cell

6 Months

Pre-filter

2 Months

Fig. 3

Pre-Filter Timer Setting

The GREEN LED lights are used to set the pre-filter cleaning interval for one, two, or three
months. The number of illuminated GREEN LED lights indicates the current setting. The factory

setting is 2 months.

Collection Cell Timer Setting

The YELLOW LED lights are used to set the collection cells cleaning interval for two, four, six, or
nine months. The number of illuminated YELLOW LED lights indicates the current setting as

shown in Figure 5. The factory setting is 6 months.

Field Charger Power Level Setting

The RED LED lights are used to set the power level of the field charger for maximum, medium, or
minimum. The number of illuminated RED LED lights indicates the current setting as shown in

Figure 6. The factory setting is for maximum.

Lower settings will reduce the slight sound emitted by the unit with minimal loss of air cleaning
efficiency, if desired.
Lower settings will also further reduce the very low ozone produced by the air cleaner. The U.S.
Food and Drug Administration recommends indoor ozone concentrations should not exceed 50
parts per billion. Your air cleaner will contribute only 5 parts per billion at the factory setting and
can be reduced to 3 parts per billion at the minimum setting.