WARNING: To reduce the risk of electric shock, this appliance
has a three-pronged plug. This plug will fit in a polarized wall
outlet only one way. If the plug does not fit fully in the outlet,
contact a licensed electrician to install a proper outlet. DO NOT
attempt to modify the plug or defeat this safety feature.
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS!
FOR HOUSEHOLD USE ONLY
10. MC1860 Steam Vacuum is only meant to collect small amounts of moisture,
such as that produced during the steaming process. DO NOT use it to
vacuum wet surfaces, or any volume of liquid.
11. Burns could occur from touching hot metal parts, hot water or steam. Use care
when you turn a steam appliance upside down - there may be hot water in water
reservoir.
12. Steam hose may become hot during use. Use caution when handling to avoid
burns or other injury.
13. MC1860 Steam Vacuum is only meant to be used with recommended MC1860
accessories. Other types of attachments are not to be used with Steam Vacuum.
Doing so may cause injuries or damage to unit.
14. Nozzle and attachments become hot during use. To avoid injuries, DO NOT
touch nozzle while using this appliance. DO NOT attempt to change
attachments while unit is emitting steam.
15. When filling your Steam Vacuum with water, DO NOT fill water reservoir with
more than 20 oz. of water. Only water should be used in unit. Other cleaning
agents will damage unit and can cause injuries.
16. Always disconnect appliance from electrical outlet when filling with water or
emptying, and when not in use.
17. DO NOT operate unit if steam opening is blocked. Should this occur,
immediately cease usage and unplug from electrical outlet.
18. Store your MC1860 Steam Vacuum in a cool, dry place.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit fails to operate.
Unit is not plugged in.
Plug into electrical
outlet.
Household Circuit Breaker /
Ground Fault Interrupter has
tripped or blown a fuse.
Reset Circuit Breaker /
Ground Fault Interrupter, or
replace fuse. If you need
assistance, contact a licensed
electrician.
Unit fails to steam, but
Vacuum Mode functions
correctly.
Water reservoir is empty.
Refill water reservoir using
procedures on page 9 of this
manual.
Mineral build-up in unit.
Follow Removing Mineral
Build-Up procedure on page
12 of this manual.
Steam output is intermittent.
Mineral build-up in unit.
It is normal for unit to
periodically stop steaming
for a few seconds. If steam
stays off for longer periods,
follow Removing Mineral
Build-Up procedure on page
12 of this manual.
Unit is emitting excess water.
Water condensation in Hose.
Point Steam Nozzle towards
sink, tub or ground and shake
while depressing Steam
Trigger. Continue until
excess water is released.
Blockage in Hose.
Attempt to dislodge blockage
if you can see it. If not,
contact our Customer Service
Department.
Water Filtration Chamber is
full / overflow lock has
engaged.
Empty Water Filtration
Chamber.
Vacuum suction strength is
weak or non-functional
Boiler has not yet completely
heated.
Wait for the green steam
ready light to illuminate
before attempting to steam.