beautypg.com

Specifications – Tripp Lite TOUCHMASTER PC 5 User Manual

Page 7

background image

7

Specifications

No. of

AC Line Cord*

No. of Control

AC Energy

Surge

Transient

Ultimate

AC Receptacles

Length

Switches

Absorption

Suppression

Response

Dimensions

Lifetime

Model

(NEMA 5-15R)

(ft.)

Master/Aux.

(joules)

(amp spikes)**

Time

(H x W x D, in.)

Insurance

TOUCHMASTER

6

10

1/4

1280

96,000

0 ns.

15/8 x 131/4 x 121/2

$25,000

(MT-6)

TOUCHMASTER PLUS

6

10

1/4

1790

132,000

0 ns.

15/8 x 131/4 x 121/2

$25,000

(MT-6 PLUS)

COMMAND CONSOLE

6

9

1/4

1110

84,000

0 ns.

2 x 131/2 x 121/2

$15,000

(CCI 6)

COMMAND CONSOLE PLUS

6

9

1/4

1450

108,000

0 ns.

2 x 131/2 x 121/2

$15,000

(CCI 6 PLUS)

COMMAND CONSOLE COMPACT

4

8

1/1

900

72,000

0 ns.

2 x 101/2 x 141/2

$5,000

(CCC 4)

POWER CENTER (PC 5)

5

6

1/5

65

6,500

<1 ns.

21/8 x 121/8 x 13

-

(PC 5)

ALL MODELS

Rated Input Voltage: 120V AC, 50 or 60 Hz
Rated Current and Load Handling: 15 amps maximum (1800) watts, 15 amps maximum per receptacle
Circuit Breaker: 15-amp resettable
Exceeds IEEE 587 category A & B specifications.
* All line cords are 3-conductor grounded.
** High-voltage spike protection works between hot to neutral, hot to ground and neutral to ground (except PC5: hot to neutral).

TELEPHONE LINE SPECIFICATIONS (PLUS MODELS ONLY)

Clamping Voltage: 260V peak +/- 10%
Response Time: <1 picosecond
Peak Transient Input Voltage: 6 Kv, 10 microseconds
Input/Output Connectors: two female "RJ" style modular jacks (phone cable included);
2-wire, single-line protection