Specifications
No. of
AC Line Cord*
No. of Control
AC Energy
Surge
Transient
Ultimate
AC Receptacles
Length
Switches
Absorption
Suppression
Response
Dimensions
Lifetime
Model
(NEMA 5-15R)
(ft.)
Master/Aux.
(joules)
(amp spikes)**
Time
(H x W x D, in.)
Insurance
TOUCHMASTER
6
10
1/4
1280
96,000
0 ns.
15/8 x 131/4 x 121/2
$25,000
(MT-6)
TOUCHMASTER PLUS
6
10
1/4
1790
132,000
0 ns.
15/8 x 131/4 x 121/2
$25,000
(MT-6 PLUS)
COMMAND CONSOLE
6
9
1/4
1110
84,000
0 ns.
2 x 131/2 x 121/2
$15,000
(CCI 6)
COMMAND CONSOLE PLUS
6
9
1/4
1450
108,000
0 ns.
2 x 131/2 x 121/2
$15,000
(CCI 6 PLUS)
COMMAND CONSOLE COMPACT
4
8
1/1
900
72,000
0 ns.
2 x 101/2 x 141/2
$5,000
(CCC 4)
POWER CENTER (PC 5)
5
6
1/5
65
6,500
<1 ns.
21/8 x 121/8 x 13
-
(PC 5)
ALL MODELS
Rated Input Voltage: 120V AC, 50 or 60 Hz
Rated Current and Load Handling: 15 amps maximum (1800) watts, 15 amps maximum per receptacle
Circuit Breaker: 15-amp resettable
Exceeds IEEE 587 category A & B specifications.
* All line cords are 3-conductor grounded.
** High-voltage spike protection works between hot to neutral, hot to ground and neutral to ground (except PC5: hot to neutral).
TELEPHONE LINE SPECIFICATIONS (PLUS MODELS ONLY)
Clamping Voltage: 260V peak +/- 10%
Response Time: <1 picosecond
Peak Transient Input Voltage: 6 Kv, 10 microseconds
Input/Output Connectors: two female "RJ" style modular jacks (phone cable included);