RDVDSN Series Direct Vent Gas Fireplace

20007894

IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.

Air Shutter Settings

Opening

Model

“A”

33RDVDSN

1/32” (1.0 mm)

33RDVDSP

3/8” (9.5 mm)

36RDVDSN

1/32” (1.0 mm)

36RDVDSP

3/8” (9.5 mm)

39RDVDSN

1/32” (1.0 mm)

39RDVDSP

3/8” (9.5 mm)

NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.

T203

Air shutter

12/12/03 djt

T203

Opening
“A”

Fig. 51 Air shutter opening.

Conversion Kits

Change Natural Change Propane

Model

to Propane

to Natural

33RDVDSN

20007864*

--

33RDVDSP

--

36RDVDSN

20007891*

--

36RDVDSP

--

39RDVDSN

20007903*

--

39RDVDSP

--

* Included with fireplace.

Normal and High

Direct Vent Units - Inputs - Orifice Size - Altitude

BTU/Hr

Manifold Pressure

Orifice 0 - 2000ft. Altitude in USA

Model

Max. Input

@ Max.

Orifice 0-4500ft Altitude in Canada

33RDVDSN

18,000

3.5”w.c.

#47 DMS

33RDVDSP

18,000

10.0” w.c.

#56 DMS

36RDVDSN

20,000

3.5” w.c.

#45 DMS

36RDVDSP

20,000

10.0” w.c.

#55 DMS

39RDVDSN

22,000

3.5” w.c.

#43 DMS

39RDVDSP

22,000

10.0” w.c.

#54 DMS