beautypg.com

Off on, Selecting control options – Toro Plus Series Satellite User Manual

Page 3

background image

Selecting Control Options

A set of eight DIP switches, located beneath the upper left corner of the control panel (as illustrated below)
is provided for the selection of optional control characteristics. Power to the controller must be turned Off
and the control panel removed from the cabinet in order to make switch position changes. When power is
switched on, the controller will automatically reconfigure to the new switch settings (with the exception of
switch 5). See *Note below.

The controller is shipped from the factory in the following configuration:

Switch 1 ON and Switch 2 ON – Enables the controller to run eight programs concurrently.

• Option – Switch 1 OFF and Switch 2 ON – Enables the controller to run only six programs

concurrently.

• Option – Switch 1 OFF and Switch 2 OFF – Enables the controller to run only four programs

concurrently.

• Option – Switch 1 ON and Switch 2 OFF – Enables the controller to run only two programs

concurrently.

Switch 3 ON – Time is displayed in a.m./p.m. format.

• Option – Switch 3 OFF – Time is displayed in 24-hour format (00:00–23:59)

Switch 4 ON – Pump output activates at the same time as station output.

• Option – Switch 4 OFF – Pump output starts 5 seconds prior to station output. (Enables pump to reach

pressure prior to station operation.)

Switch 5 ON – Active day change occurs at midnight (12:00 a.m.[00:00])

• Option – Switch 5 OFF – Day change occurs at 6:00 a.m. (06:00)

*Note: This change requires initialization to activate. See page 14 for initialization procedure.

Switches 6, 7 & 8 are non-functional.

To change the DIP switch positions:

1. Switch the power Off at controller power supply.

2. Remove the timing mechanism from the top of the pedestal cabinet. (The cables attached to the timing

mechanism can remain connected for this procedure).

3. Locate the DIP switches mounted on top left corner of timing mechanism PCB.

4. Using a pen tip or small screwdriver, reset the DIP switches as required. (Do not use a pencil for this

procedure. Loose graphite from the pencil can damage the switch mechanism).

5. Reinstall the timing mechanism and switch on the power.

3

1 2

3 4

5 6

7 8

OFF

ON

Address

% Adjust

Time/Day

Week 1

Central

Stand
Alone

Off

Cycle

Syringe

Multi
Manual

Start
Times

Active
Days

Run
Times

ENTER

START

EXIT

STOP

1 2 3 4 5 6 7

8 9 10 11 12 13 14

Week 2

R

LTC

TM

Tu

Programs

Plus