Troubleshooting Reference Chart

PROBLEM/

SYMPTOM

PROBABLE

CAUSE

LOCATION

REASON - CORRECTION

Ionizing Section of Cell

1. Dirty insulator(s) – Clean
2. Defective insulator(s) – Replace
3. Foreign Object Between Ionizing Bar and Ground

electrode - Remove

Collecting Section of Cell

1. Dirty insulator(s) - Clean
2. Defective insulator(s) – Replace
3. Foreign Material Bridging Plates - Remove
4. Bent Plates – Straighten or Replace

High Voltage Leads

1. Disconnected High Voltage Lead Contacting Ground

- Reconnect

2. Defective Lead/Insulation Breakdown – Replace

Entire Lead

Indicating Light
Not Glowing

Short Circuit

Power Supply

Charred/Over Heated Components – Replace
Power Supply

Control

1. Disconnected Supply Line Power – Reconnect
2. Faulty indicting Light - Replace

Power Supply

1. Blown Fuse – Replace Power Supply
2. Disconnected Wire – Replace
3. Charred/Over Heated Components – Replace

Power Supply

Indicating Light
Not Glowing

Open Circuit

Electronic Air Cleaner
Housing

1. Electrical Interlock Switch Not Closed – Close

Access Door

2. Faulty Electrical Interlock Switch - Replace

Indicating Light
Flickering

High Resistance
Short

High Voltage Circuit

1. Ionizer High Voltage Lead Connected to Plate

Section and Plate Lead to Ionizer – Reconnect
Leads

2. Loose or Disconnected High Voltage Lead-Tighten

or Reconnect

3. Loose or Defective Intercell Connection (on Multicell

Units) – Tighten or Replace

4. Foreign Object Adrift in Ionizer or Plate Section of

Cell - Remove