Technical specification, Troubleshooting, Continued – Transition Networks SISTF10XX-160-LR(T) User Manual
Page 9

16
SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Test
Description
Test Levels
IEC 60068-2-6
Vibration
10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes)
IEC 60068-2-27
Shock
50 g, 11 ms, +/-X, +/-Y, +/- Z (6 direction)
IEC 60068-2-32
Free fall
75 cm, 1 corner, 3 edges, 6 faces (total 10 drops)
Environmental Type Tests
Test
Description
Test Levels
Severity
IEC61000-4-2 ESD
Air discharge
+/- 8 KV
3
Contact discharge
+/- 6 KV
3
ESD contact discharge
+/- 6 KV
3
IEC61000-4-3 Radiated RFI
Housing
10V/m, 80 MHz - 1 GHz
AM 1 KHz, 80% mod
10 V/m, 0.9 - 1.8 GHz
FM 200 Hz 50% square
3
IEC61000-4-4 Burst
(Fast Transient)
Power supply lines
+/- 2 KV
3
Communication lines
+/- 1 KV
3
Relay
+/- 1 KV
3
IEC61000-4-5 Surge
Power supply lines
+/- 2 KV, 12
Ω, CM
+/- 1 KV, 2
Ω, DM
3
Relay
+/- 2 KV, 12
Ω, CM
+/- 1 KV, 2
Ω, DM
3
IEC61000-4-6 Induced
(Conducted RFI)
Power supply lines
10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod
3
Communication lines
10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod
3
Relay
10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod
3
EMS Type Tests
Technical Specification
-- Continued
This device has been evaluated as EEx nC IIC T4 equipment under DEMKO
Certificate No. 03 ATEX 0324537U. Each module is suitable for use in Zone 2
Explosive Atmospheres. The device must be installed in a minimum IP 54
enclosure as defined in IEC 60529 and EN 60529.
This device is a building-in type. The installation into a certain end equipment
shall comply with fire enclosure request of IEC 60950/EN60950 or similar
sentence.
[email protected] -- Click the “Transition Now” link for a live Web chat.
17
Troubleshooting
If the device fails, isolate and correct the fault by determining the answers to the
following questions and then taking the indicated action:
1.
Is the PWR1 LED illuminated?
NO
•
Ensure the power source is the proper voltage (12 - 48 VDC).
•
Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR1”.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the PWR2 LED illuminated?
NO
•
Ensure the power source is the proper voltage (12 - 48 VDC).
•
Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR2”.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the FAULT LED illuminated?
YES
•
If one or more port alarm switches (1 - 5) is ON
,
the device lost the
corresponding fiber or copper link, or the primary power or backup
power.
•
Ensure the problem copper or fiber link is properly connected.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 4.
4.
Is a 100M LED (near a fiber link) illuminated?
NO
•
Check the corresponding fiber cables for proper connection.
•
Verify that the TX and RX cables on the device are connected to the
RX and TX ports, respectively, on the other device.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 5.