Tricity Bendix SIG 233/1 User Manual
Page 23

23
LPG flexible connections must be of a type 
suitable for LPG and capable of operation up 
to 50mbar and to carry a red strips, band or 
label.
- The appliance flexible connector should not
be subjected to undue forces either in normal 
use or whilst connected or disconnected; The 
socket which the plug of the appliance 
flexible connector fits should be permanently 
attached to a firmly fixed gas installation pipe 
and positioned such that the appliance 
flexible connector hose hangs freely 
downwards (see fig.); 
- The appliance flexible connector should be
positioned such that it will not suffer 
mechanical damage, e.g. abrasion from the 
surrounding kitchen furniture, which may be 
moved in use such as a drawer or door, or by 
being trapped by any stability device. 
 
The plug-in-connector bayonet should be 
accessible for disconnection after moving the 
appliance. 