Installation

15

EAC20002025

EAC14001625

EAC14002020

Unit Dimensions

10

For Qualified HVAC

Installer Only

TYPICAL MOUNTING POSITIONS
(Air cleaner shown shaded in illustrations)

Horizontal Furnace
Mounted vertically in return
duct as close to the furnace
as possible.

Offset Installation If there is less
than 7-in. for mounting the air
cleaner between the duct and the
furnace, move the return air drop.

Space Saver
Furnace
(Highboy) Side
installation.
Mounted
vertically, where
return air enters
side inlet of
furnace.

Counterflow
Furnace
Mounted
horizontally in
return duct
just above the
furnace.

Basement Furnace
(Lowboy) Mounted
horizontally in return
plenum just above
the furnace.

Before making changes to a HVAC system
that may affect the ventilation of
fuel-burning appliances, contact your
heating contractor.

WARNING

Transitions

Before

After

Transitions