beautypg.com

3 quick start list for stand-alone, Figure 2–2 – Texas Instruments TPA6110A2 MSOP User Manual

Page 14

background image

Quick Start List for Stand-Alone

2-4

Operation

2.3

Quick Start List for Stand-Alone

Follow these steps to use the TPA6110A2 MSOP EVM stand-alone or when
connecting it to existing circuits or equipment. Connections to the TPA6110A2
MSOP module header pins can be made via individual sockets,
wire-wrapping, or soldering to the pins, either on the top or the bottom of the
module circuit board. Numbered callouts for selected steps are shown in
Figure 2–2 and details appear in Chapter 3.

Figure 2–2.

Quick Start Module Map

6

2

4

4

5

6

GND

Vo2

C3

IN2

GND

VDD GND

IN1
GND

U1

R1

R2

C2

R3

S1

Shutdown

C5

Vo1

GND

C1

TEXAS

INSTRUMENTS

SLOP338

TPA6110A2 MSOP EVM

C4

R4

R5

† Due to the very small size of the MSOP IC package, the standard part number TPA6110A2 is

replaced with the code TIAIZ.

-

Power supply

1) Ensure that all external power sources are set to off

.

2) Connect an external regulated power supply set to 5 V to the module V

DD

and GND pins, taking care to observe marked polarity.

-

Inputs and outputs

3) Ensure that the signal source level is set to minimum.

4) Connect the audio source to the module IN1, IN2, and GND pins, taking

care to observe marked polarity.

5) Connect the shutdown (S1) pin to V

DD

through a normally open switch.

6) Connect 32-

headphones to the module V

O1

, and V

O2

pins through 33

µ

F to 1000

µ

F output-coupling capacitors (see Figure 2– 3) and return to

the GND pin, or

7) For line output, connections to the V

O1

and V

O2

pins must be made

through 33

µ

F to 1000

µ

F output-coupling capacitors and returned to

GND.

-

Power-up

8) Verify correct voltage and input polarity and set the external power supply

to

ON.

The EVM should begin operation.

9) Adjust the signal source level as needed.