beautypg.com

Texas Instruments TPA0202 User Manual

Page 16

background image

Quick Start List for Stand-Alone

2-6

Quick Start

-

Evaluation Module Preparations

6) To have the module amplifier IC enter the shutdown mode when the

module mute control input is activated, set shutdown jumper S1 to

ON. To

have the amplifier IC only mute when the module mute control input is
activated, set shutdown jumper S1 to

OFF.

7) To select the line inputs, set input select jumper S3 to

OFF. To select the

headphone inputs, set input select jumper S3 to

ON.

8) To allow the module SE/BTL control input to switch the amplifier IC

between single ended (SE) and bridge-tied load (BTL) output modes, set
output mode jumper S4 to

OFF. To keep the module amplifier IC in the

single-ended output mode regardless of the control input state, set jumper
S4 to

ON.

9) Set V

DD

bridge jumper S5 to

ON to connect the RVDD and LVDD module

power input pins together, or to

OFF to keep the two power inputs isolated

on board

10) To automatically select the headphone inputs when the single-ended

output mode is selected by the module SE/BTL control input, set
autosense control jumper

S6 to ON. To isolate the amplifier IC input select

pin from the module output mode select control input, set autosense
control jumper

S6 to OFF.

11) Set junction temperature measurement jumper S8 to

OFF for normal

operation

-

Control Inputs

12) Connect control lines to the various module control input pins as needed:

a) HP/L*: A high selects the headphone input pins; a low or float selects

the line input pins.

b) SE/BTL*: A high selects the single-ended output mode; a low or float

selects the bridge-tied load output mode.

c)

MUTE: A high mutes the amplifier IC on the module; a low or float
allows normal operation.

-

Power-up

13) Verify correct voltage and input polarity and set the external power supply

to

ON.

The EVM should begin operation.

14) Adjust the signal source level as needed.