TDK Ceramic Capacitors FD Series User Manual
Page 3
(2/2)
005-01 / 20110630 / e4e39a_fd.fm
• All specifications are subject to change without notice.
TYPICAL CAPACITANCE CHARACTERISTICS
CAPACITANCE vs. TEMPERATURE CHARACTERISTICS
CAPACITANCE vs. AC VOLTAGE CHARACTERISTICS
PRECAUTIONS
(1) During transportation and storage
• Do not transport or store where the capacitor will be exposed to
high temperature or high humidity.
• Do not expose to poisonous gases such as H
2
SO
4
, HCl, or
HNO
3
.
• Avoid excessive impact such as that caused by falling.
(2) During operation
• Avoid contact with electrolytes such as perspiration. Do not
touch with bare hands.
• Avoid excessive impact such as that caused by falling.
• Do not apply solder to stud terminals.
• Do not re-machine the terminals.
(3) Usage
• Make sure that the capacitor is not exposed to radiant heat from
chambers or transformers.
50
30
10
–10
–30
–50
–50
0
50
100
Capacitance change rate(%)
Temperature(˚C)
Y5P
1
0
–2
–1
–3
–4
0
50
100
150
Capacitance change rate(%)
Rated voltage(%)