Installation – TOA Electronics F-2352C2 User Manual
Page 5
When mounting the speaker to a ceiling, check in advance that the ceiling structure is of drop ceiling with
2-foot standard ceiling tiles.
5
5. INSTALLATION
The F-2322C2 and F-2352C2 can be mounted in 2 different configurations:
• Mounting to a drop ceiling
Use the supplied tile bridge.
If the mounting hole is larger than the specified diameter, use the optional HY-TR1 Trim Ring together
with the supplied tile bridge.
• Hanging from a ceiling suspension pipe (exposed installation)
Use the optional HY-BC1 Back Can.
Ceiling tile
ø200 ±5 mm (7
7
/
8
±
13
/
64
")
Step 1. Cut a ø200 mm (7
7
/
8
") hole in the ceiling.
Use the supplied paper pattern to position
and trace the hole.
Step 2. Mount fittings to a ceiling or hanging pipe.
2-1. Mounting to a drop ceiling
Caution
Set the tile bridge so that both ends fit securely into the T-grids, even if the ceiling tile accidentally
falls off.
Place the supplied tile bridge on the 2-foot
tile as shown at right.
T-grid
2-foot tile
Tile bridge (accessory)
Ceiling tile
T-grid
Tile bridge (accessory)