beautypg.com

6test results / performance data, 1 efficiency and power loss, 2 closed loop performance – Texas Instruments HPA070 User Manual

Page 11

background image

SLUU186 − March 2004

11

TPS40055-Based Design Converts 12-V Bus to 1.8 V at 15 A (HPA070)

6

Test Results / Performance Data

6.1

Efficiency and Power Loss

Figure 3 shows the efficiency as the load is varied from 1 A to over 15 A. The typical efficiency remains over
90% as the load ranges from 3 A to 12 A.

Figure 3

0

88

78

2

86

80

90

94

4

6

8

10

12

14

16

82

84

92

IOUT − Output Current − A

Efficiency − %

EFFICIENCY

vs

LOAD

Figure 4

0

0

2

4

1

2

3

4

6

8

10

12

14

16

5

6

7

IOUT − Output Current − A

P

DISS

− Power Dissipation − W

POWER DISSIPATION

vs

LOAD

6.2

Closed Loop Performance

100

100 k

10 k

1 k

20

−30

10

−20

30

50

−10

0

40

100

0

80

20

120

160

40

60

140

f − Frequency − kHz

Gain − dB

Phase −

°

OVERALL GAIN AND PHASE

vs

FREQUENCY

Gain

Phase

Figure 5.