7 External Connections

RS-232-C devices are classified by their function as either Data Terminal

Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal
equipment is defined as the communication source and data communication equipment
is defined as the device that provides a communication channel between two DTE-type
devices.

Telephone

line

DCE

DCE

DTE

DTE

RS-232-C

RS-232-C

Modem

Modem

Terminal

Terminal

Figure 16 --- Use of DTEs and DCEs in a communications link

DTE- and DCE-type devices have complementary pinouts to allow terminals

and modems to be connected directly using a one-to-one cable as shown in Figure 16.
In many applications, DCEs are unnecessary, and in these cases a cable called a "null
modem cable" or "modem eliminator cable" is used to directly connect two DTE-type
devices. A typical null modem cable is also shown in Figure 16.

RxD
TxD
RTS
CTS
DTR
DSR
DCD

GND

(3)
(2)
(4)
(5)

(20)

(6)
(8)

(22)

(7)

RI

TxD
RxD
CTS
RTS
DSR
DTR
DCD

GND

(3)
(2)
(4)
(5)
(20)
(6)
(8)
(22)
(7)

RI

RxD
TxD
RTS
CTS
DTR
DSR
DCD

GND

(3)
(2)
(4)
(5)

(20)

(6)
(8)

(22)

(7)

RI

DCD

GND

(8)
(22)
(7)

Typical DTE-to-DCE cable

RI

DCD

GND

RxD
TxD
RTS
CTS
DTR
DSR

(3)
(2)
(4)
(5)

(20)

(6)

(8)

(22)

(7)

RI

DCD

GND

(8)
(22)
(7)

RxD
TxD
RTS
CTS
DTR
DSR

(3)
(2)
(4)
(5)

(20)

(6)

Typical DTE-to-DTE null modem cable

Figure 17 --- Cabling requirements for RS-232-C devices