Installation, Warning, 2100 millennium wood stove (acc) – Quadra-Fire 2100 Millennium Wood 21M-ACC User Manual
Page 11: A. hearth protection requirements, Usa canada
May 5, 2011
7039-131H
Page 11
2100 Millennium Wood Stove (ACC)
R
A. Hearth Protection Requirements
FLOOR PROTECTION: Floor protector must be non-com-
bustible material, extending beneath heater and to the front,
sides and rear as indicated. The floor must be non-com-
bustible or otherwise adequately protected from radiant heat
given off by the unit and from sparks and falling embers. A
layer of thin brick or ceramic tile over a combustible floor is
not sufficient.
In US installations, it is necessary to install a floor protector
of a minimum of 3/8 inch (9.5mm) thick metal clad millboard
or equivalent a minimum of 16 inches (406mm) in front of
glass and 8 inches (203mm) to both sides of the fuel loading
door. Open the door and measure 8 inches (203mm) from
the side edge of the opening in the face of the appliance.
*
See exception.
16" from glass
8 in.
USA
Fuel loading door
5-3/4 in. 2-1/4 in."
29-5/8 in.
minimum
39 in.
minimum
29
-5/
8 i
n.
25
-3/
8 i
n.
32-7/8 in.
39
in.
3 in.
13
5°
op
tio
na
l
co
ve
rag
e
50-3/4 in.
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
203mm (8 in.)
203mm
(8 in.)
203mm
(8 in.)
457mm (18 in.)
1244mm
(49 in.)
minimum
1000mm (39-3/8 in.)
minimum
In Canada, similar floor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *
See exception.
*EXCEPTION: Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 11.4.
USA required
Canada recommended
Figure 11.3
4
Installation
Figure 11.1
Figure 11.2
Figure 11.4
WARNING
Fire Risk.
• Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
NOTE:
• Illustrations and photos reflect typical installations and are FOR DESIGN PURPOSES ONLY.
• I
llustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design preference
• Hearth & Home Technologies reserves the right to alter its products.
USA
USA
CANADA