beautypg.com

Air conditioner inst alla tion, Part identifica tion – QUASAR HQ-2122UH User Manual

Page 4

background image

1 Air inlet louver

4 Air filter (behind the

front intake grille)

2 Cabinet

5 Front intake

grille

3 Power cord

6 Front grille

7 Vertical airflow direction vane

(Airflow direction adjustment up-
down).
The vertical airflow direction vane
is controlled by rotating the
horizontal vane forward or backward.

2

AIR CONDITIONER INST

ALLA

TION

3

P

ART IDENTIFICA

TION

REMOVAL OF FRONT GRILLE

1

Remove the front intake grille.

Pull up the front intake
grille about 90° and slide
it slightly to the left to
unhook the tabs.

2

Remove the air filter.

Tilt up and pull
out the air filter
by the holder.

3

Remove the front grille.

a

a

a

a

a At bottom right side of the front grille, press inward on cabinet near the power cord, and pull

the grille outward to the right until right tab releases.

b

b

b

b

b At the bottom left side, push inward on cabinet and pull the grille outward to the left to release

the left tab.
Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from
damage.

c

c

c

c

c Slide the front grille upwards to free the two top tabs from slots at the top of the cabinet.

HOW TO ATTACH THE DRAIN PAN (OPTIONAL)

Maximum
13/32”

Condensed water

This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed
water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
If the splashing sound annoys you, you can provide an outside drainage by using the following
procedure which may, however, cause a small loss of performance.
Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate

drainage. (Max. 13/32”)

Condensed water drainage

1

Remove the rubber plug and slide the chassis out from
the cabinet.

Remove the
rubber plug

OFF

/ON

OPE

RATIO

N

TEMP

/TIME

R

COO

L

FAN

HIGH

MED

LOW

MOD

E

FAN

SPEE

D

SET

TIME

R

SET/
CAN

CEL

AIR S

WING

ECO

NOM

Y

hr

°F

Wirele

ss

R e m

o t e

C o n

t r o l

2

Install the optional drain pan (part no. CWH40175).

Screws

INTERNAL VIEW

Drain pan (optional)

Install the drain pan at the right
corner of the cabinet using 2
screws (part no. CWG86C733).

3

Connect a drain hose (optional).

Fit the drain hose to the drain pan.

Under-side view with drain
pan and hose in place.

Drain hose
(not included)

4

Slide the chassis back into the
cabinet.
Reinstall the cabinet screws.
Secure the cabinet to chassis by
using screws.

Note
The drain pan (part no.
CWH40175) can be obtained
from nearest service center.

MAIN UNIT

OFF/ON

OPERATIO

N

TEMP/TIM

ER

COOL
FAN

HIGH
MED
LOW

MODE

FAN SPEE

D

SET

TIMER

SET/

CANCEL

AIR SWIN

G

ECONOM

Y

hr

°F

Wireless

R emote C

o ntrol

9 Touch control panel

OFF/ON

OPERATION

TEMP/TIMER

COOL

FAN

HIGH

MED

LOW

MODE

FAN SPEED

SET

TIMER

SET/

CANCEL

AIR SWING

ECONOMY

hr

°F

Wireless

R e m o t e C o n t r o l

a Display Panel
b MODE selection pad
c FAN SPEED selection pad
d TEMPERATURE/TIMER

setting pad

e TIMER pad
f Timer SET/CANCEL pad
g OPERATION OFF/ON pad
h AIR SWING pad
i ECONOMY pad

a

b

c

d

e

f

g

h

i

Note
Drain hose or tubing can be
purchased locally to satisfy your
particular needs.

TYPES OF SIGNAL SOUND
One long “Beep” and one short “Beep”. (Sound from the main unit.)

EXTERNAL VIEW

1

2

3

4

5

6

8

7

9

OFF/ON

OPERATION

TEMP/TIMER

COOL
FAN

HIGH
MED
LOW

MODE

FAN SPEED

SET

TIMER

SET/

CANCEL

AIR SWING

ECONOMY

hr

°F

Wireless

R emote C

o ntrol

Air filter

OFF/ON

OPERATIO

N

TEMP/TIME

R

COOL
FAN

HIGH
MED
LOW

MODE

FAN SPEE

D

SET

TIMER

SET/

CANCEL

AIR SWING

ECONOMY

hr

°F

Wireless

R emote C

o ntrol

a

a

a

a

a

b

b

b

b

b

c

c

c

c

c

OFF/ON

OPERATION

TEMP/TIMER

COOL
FAN

HIGH
MED
LOW

MODE

FAN SPEED

SET

TIMER

SET/

CANCEL

AIR SWING

ECONOMY

hr

°F

Wireless
R emote C

o ntrol

OFF/ON

OPERATIO

N

TEMP/TIMER

COOL

FAN

HIGH

MED
LOW

MODE

FAN SPEED

SET

TIMER

SET/

CANCEL

AIR SWING

ECONOMY

hr

°F

Wireless

R emote C

o ntrol

8 Ventilation lever

The ventilation lever must be in the CLOSE position in order to
maintain the best cooling conditions. When fresh air is necessary
in the room, set the ventilation lever to the OPEN position. The
damper is opened and room air is drawn out.

OFF/ON

OPERATIO

N

TEMP/TIM

ER

COOL

FAN

HIGH

MED

LOW

MODE

FAN SPEED

SET

TIMER

SET/

CANCEL

AIR SWING

ECONOM

Y

hr

°F

Wireless

R emote C

o ntrol

HQ-2102/2122UH (EN)

9/12/03, 2:12 PM

4

This manual is related to the following products: