beautypg.com

Nput and, Utput, Onnections – Omega Speaker Systems iDRN-PS-1000 User Manual

Page 12

background image

4.3 Wiring (Continued)
230Vac - Two phase power wiring

Figure 4.3— Wiring for 230Vac - Two Phase

I

NPUT AND

O

UTPUT

C

ONNECTIONS

4

10

L N

+ -

Output Voltage

(for shielded wire
connections, if necessary)

Earth

FUSE 1

L1

Switch

L 2

Earth

FUSE 2

Switch

*

*

USE A SWITCH TO APPLY

+24V POWER TO THE LOAD,
IF THE CAPACITANCE OF
THE LOAD WILL DRAW MORE
THAN 7 AMPS AT TURN ON.

Earth
Return

+24 V

To Signal

Conditioner

Modules

Input Power

USE AWG 12-26 WIRE