beautypg.com

Built-in central heating water circulating pump, Pump performance curve grundfos ups 15-50 – Optima Company 1001 User Manual

Page 12

background image

1001

12

Built-in Central Heating Water Circulating Pump

The pump head available for circulating the water is given in fig. 8.

N.B. - The pump is factory set at position 3. The pump is a Grundfos type 15-50 UPS series.

Grunfos Pump performance graph

Note - Minimum flow through boiler heat exchanger at any time should not fall below 6 litres per minute.

If required an additional expansion vessel may be fitted to the central heating return inlet.

If the total volume of water in the system exceeds 40 litres an additional expansion vessel must
be fitted to the central heating return inlet.

Pump performance curve Grundfos UPS 15-50

1 2 3 Speed settings
A Boiler pressure drop
B Max. available pump head C.H.

Fig. 8

SIZING OF ADDITIONAL EXPANSION VESSELS:
Deduct from the value given in the table the 7 litre
vessel supplied.

Note
1.
Fill C.H. installation to min. 1.5 bar.
2. Select by preference the expansion vessel for

increased system pressure of 2.0 bar

3. Expansion vessel must be fitted to Central Heating

Return Inlet

4. The standard 7 litres expansion vessel is charged

to 1 bar

Fig. 9

SAFETY VALVE
SETTING (bar)

VESSEL CHARGE
PRESSURE (bar)

INITIAL SYSTEM
PRESSURE (bar)

TOTAL WATER
CONTENT of SYSTEM

3.0

0.5

1.0

1.5

1.0

1.5

2.0

1.5

2.0

2.0

EXPANSION VESSEL VOLUME (litres)

LITRES

25

3.5

6.5

13.7

4.7

10.3

8.3

50

7.0

12.9

27.5

9.5

20.6

16.5

75

10.5

19.4

41.3

14.2

30.9

24.8

100

14.0

25.9

55.1

19.0

41.2

33.1

125

17.5

32.4

68.9

23.7

51.5

41.3

150

21.0

38.8

82.6

28.5

61.8

49.6

175

24.5

45.3

96.4

33.2

72.1

57.9

200

28.0

51.8

110.2

38.0

82.4

66.2

0.140

0.259

0.551

0.190

0.412

0.33

For syst. volumes other than
those given above, mult. the syst.
volume by the factor across