2.0 SPECIFICATIONS
2.1 INPUT
Current
1-5 mA, 4-20 mA or 10-50 mA
Protection
200 mA max forward and 1000 mA max
reverse
Voltage Drop
2.5 V max forward and 1.2 V max reverse
Span Range
100 to 2000 counts continuous adjustment
with a multiturn potentiometer
Zero Range
The multiturn zero potentiometer can displace
the displayed reading by ±500 counts from the
center of each of the four overlapping zero
ranges, provided that the resultant is within the
±1999 count display capability.
Span Slope
Positive or Negative
Normal Mode Rejection
at 50/60 Hz
46 dB minimum
2.2 ACCURACY AT 25°C
Maximum error
±0.1% R ±1 count
Zero tempco
±0.1 ct/K typ, ±0.3 ct/K max
Span tempco
±0.005%S/K typ, ±0.015%S/K max
2.3 CONVERSION
Technique
Dual-slope, average value with autozero
correction
Polarity
Determined automatically at the end of input
integration period
Input integration period
100 milliseconds (nominal value)
Reading rate
2.5/second