Super, Dust gorilla system, Dust gorilla cfm vs. sp curve – Oneida Air Systems Super Dust Gorilla User Manual
Page 5

III. General Specifications & Fan Performance Curves
2HP Super Dust Gorilla Owners Manual
O.A.S. 2007
c
4
- Sleeve kit adds 7 (4 is minimum)
- 35 gal. bin is 22 dia. x 22.5 h / 55 gal. bin is 22 dia. x 35.5 h
- Several Filter Options Available- Galvanized steel construction
- The collector can be hung on the wall, from the ceiling, or free standing support using
the 10 ga. angle iron ring at the top of the cone.
(See assembly instructions)
2.0 hp
Height without
Dust Bin
Cyclone
Diameter
Inlet
Diameter
Weight without
Dust Bin
TEFC
Motors
Class F
115/230v
23/11.5 amps
1.15 Service Factor
63
21
7
Approx. Wt.
122 lbs.
w/o drum or filter
Static pressure and volume together determine
a fans performance. Several factors, such as
layout of ductwork and diameter of openings,
can affect a fans performance.
2hp
Super
Dust Gorilla System
Industrial Baldor TEFC 2hp motor
*
115/230v - 23/11.5 amps / 1.15 Service Factor
Full 16 gauge galvanized cyclone & 11 ga. fan housing
7 dia. inlet / 8 rectangular outlet
14.25 dia. x 4 wide cast aluminum fan wheel
back inclined non-sparking, non-ferrous dynamic, two-planed
balanced to ISO 6.3 specifications.
Sound 78 - 79dB @ 10 with Built-in Silencer and Filter
95 Sq. Ft. Filter Media / Spun-Bonded
2hp
Super
Dust Gorilla CFM vs. SP Curve*
9
8
7
6
5
4
3
2
0
St
atic Pressure at Cyclone Inlet
CFM
0
200
400
600
1000
800
10
1400
1600
6.3
1200
10.65
9.4
4.3
11
8.25
3
2.3
1422 cfm @
2.3 SP w/c
w/o filter.
Vented outside.
- Without Filter
- With Filter
*Fan curves vary slightly with different filter packages.
1349 cfm @ 2.3
SP w/c w/ filter.
FCS133900
1422 CFM @ 2.3 SP w/c w/o filter
*
* Note: Motor Starter supplied
with system is for 220v only.