Maintenance, Troubleshooting – Omega Lift 40500 User Manual
Page 5

5
MAINTENANCE
Important: Use only good grade hydraulic jack oil. Avoid
mixing different types of fluid and NEVER use brake
fluid, turbine oil, transmission fluid, motor oil or glycerin.
Improper fluid can cause premature failure of the jack
and the potential for sudden and immediate loss of load.
Mobil DTE 13M or equivalent recommended.
Adding oil
1. With lifting arm fully lowered set jack in its upright,
level position. Locate and remove oil filler plug.
2. Fill with oil until ~3/16" above the inner cylinder as
seen from the oil filler hole. Reinstall oil filler plug.
Changing oil
For best performance and longest life, replace the
complete fluid supply at least once per year.
1. With lifting arm fully lowered, remove oil filler plug.
2. Lay the jack on its side and drain the fluid into a
suitable container.
Note. Dispose of hydraulic fluid in accordance with
local regulations.
3. Fill with oil until ~3/16" above the inner cylinder as
seen from the oil filler hole. Reinstall oil filler plug.
Lubrication
A periodic coating of light lubricating oil to pivot points,
axles and hinges will help to prevent rust and assure that
wheels, casters and pump assemblies move freely.
Cleaning
Periodically check the pump piston and ram for signs
of rust or corrosion. Clean as needed and wipe with
an oily cloth.
Note: Never use sandpaper or abrasive material on
these surfaces!
Storage
When not in use, store the jack with lifting arm fully
lowered.
TROUBLESHOOTING
Symptom
Possible Causes
Corrective Action
Jack will not lift load
• Release valve not tightly closed
• Load is too heavy
• Ensure release valve tightly closed
• Consider higher capacity jack
Jack will lift, but not maintain
pressure
• Release valve not tightly closed
• Hydraulic unit malfunction
• Ensure release valve tightly closed
• Contact Omega Tech. Service
Jack will not lower after unloading
• Reservoir overfilled
• Linkage binding
• Ensure load is removed, then drain
fluid to proper level
• Clean and lubricate moving parts
Poor lift performance
• Fluid level low
• Air trapped in system
• Ensure proper fluid level
• With ram fully retracted, remove
oil filler plug to let pressurized air
escape, then reinstall oil filler plug
Jack will not lift to full extension
• Fluid level low
• Ensure proper fluid level