8

4-4 Advanced Functions (OSXL653)

4-4-1 AUTO Mode-Continuous
Operation

From the SCAN mode (Trigger is pulled), you can
lock the trigger electronically and measure
temperature continuously (AUTO mode) by pressing
the F key. The AUTO icon will appear on the display.
Pressing the F key again will disable the AUTO
mode. AUTO icon will disappear from the display. If
the trigger is pulled, the unit stays in the SCAN
mode. If the trigger is released, the unit will go to
HOLD mode and will shut itself off after about 6
seconds.

The following table shows an overall functional flow
chart of the thermometer:

Mode

Press F Key

Press Up Key Press Down Key

SCAN

SCAN AUTO

----

----

AUTO

AUTO

DATA

----

----

DATA

DATA Max Temp

+ Memory

- Memory

Location

Location

Max Temp Max Temp Min Temp

----

----

Min Temp Min Temp Avg Temp

----

----

Avg Temp

Avg Temp ∆T

----

----

∆T

T Emissivity

----

----

Emissivity Emissivity High Alarm

+ Emissivity

– Emissivity

HAL

High Alarm Low Alarm + Alarm Set Point – Alarm Set Point

LAL

Low Alarm SCAN/HOLD + Alarm Set Point – Alarm Set Point

Low Cost Professional Infrared Thermometer