beautypg.com

Oregon Scientific BAR636A User Manual

Page 2

background image

WEATHER FORECAST

This product forecasts the next 12 to 24 hours of weather
within a 30-50 km (19-31 mile) radius with 70 to 75 percent
accuracy. The weather forecast is always displayed.

SUNNY

PARTLY

CLOUDY

RAINY

CLOUDY

TEMPERATURE

This product can display current, minimum, and maximum
temperature information collected by the remote sensors and
main (indoor) unit.

Outdoor data is collected and displayed every 40 seconds.
Indoor data is collected and displayed every 10 seconds.

SELECT TEMPERATURE UNIT

Slide the

°

C /

°

F switch into the desired location. The switch

is located in the main unit battery compartment. The setting
for the main unit overrides the remote sensor setting.

SELECT CHANNEL NUMBER

Press CHANNEL to switch between sensors 1-3.

The icon shows the selected sensor.

To auto-scan between sensors, press and hold CHANNEL
for 2 seconds. Each sensor's data will be displayed for 3
seconds. To end auto-scan, press CHANNEL or MEMORY.

NOTE For more information on the sensor see "Remote
Sensor THN122N" section.

KINETIC-WAVE
ICON

DESIGNATED

Indoor

Remote

Remote

Remote

DISPLAY

Display

Display

Display

Display

Channel 1

Channel 2

Channel 3

MINIMUM / MAXIMUM RECORDS

The MEMORY button is located in the main unit battery
compartment. Press MEMORY to toggle between current,
maximum (MAX) and minimum (MIN) records. To clear the
records, press and hold MEMORY for 2 seconds. A beep
will sound to confirm that the memory has been cleared.

MOON PHASE

The Calendar must be set for this feature to work, see "Set
Clock" section.

• Press

or

to view the moon phase for the next or

previous day.

• Press and hold

or to scan quickly through the years

(2001 to 2099).

RESET SYSTEM

The RESET button is located in the main unit battery
compartment. Press RESET when you change the batteries
and whenever performance is not behaving as expected (for
example, unable to establish radio frequency link with remote
sensor or atomic clock).

SAFETY AND CARE

Clean the product with a slightly damp cloth and alcohol-
free, mild detergent. Avoid dropping the product or placing it
in a high-traffic location.

BACKLIGHT

Press LIGHT to activate the backlight for 8 seconds.

New Moon

Waxing Crescent

First Quarter

Waxing Gibbous

Full Moon

Waning Gibbous

Last Quarter

Waning Crescent

WARNINGS

This product is designed to give you years of service if
handled properly. Oregon Scientific will not be
responsible for any deviations in the usage of the device
from those specified in the user instructions or any
unapproved alterations or repairs of the product. Observe
the following guidelines:

• Never immerse the product in water. This can cause

electrical shock and damage the product.

• Do not subject the main unit to extreme force, shock, or

fluctuations in temperature or humidity.

• Do not tamper with the internal components.

• Do not mix new and old batteries or batteries of different

types.

• Do not use rechargeable batteries with this product.

TROUBLESHOOTING

PROBLEM SYMPTOM

REMEDY

Calendar

Strange date /

Change language

month

Clock

Cannot adjust

Disable atomic clock

clock

Cannot auto-

1. Adjust batteries

synchronize the

2. Press RESET

date and time

3. Manually activate
atomic feature

Temp

Shows "LLL" or "

Temperature is

HHH"

out-of-range

Remote

Cannot locate

Check batteries

sensor

remote sensor

Check location

Cannot change

Check sensors.

channel

Only one sensor is
working

Data does not

Initiate a manual

match main unit

sensor search

Atomic Clock

Auto or manual (disabled)

Clock display

HH:MM:SS

Hour format

12hr AM / PM
(Model BAR636A)

CLOCK

SPECIFICATIONS

MAIN UNIT DIMENSIONS

L x W x H

3.6 x 2.4 x 0.79 inches
(92 x 60 x 20 mm)

Weight

2.22 ounces (63 grams )
without battery

REMOTE SENSOR DIMENSIONS

TEMPERATURE

Display

Rainy, cloudy, partly
cloudy, sunny

WEATHER FORECAST

RF frequency

433 MHz

Range

98 feet (30 meters) with no
obstructions

Transmission

Every 40 seconds

Channel No.

1-3

REMOTE SENSOR (THN122N)

L x W x H

2.7 x 1.7 x 5.6 inches
(68.8 x 44.4 x 141.7 mm)

Weight

4.9 ounces (138 g ) without
battery

Unit

°F / °C

Indoor range

23°F to 122°F
(-5°C to 50°C)

Outdoor range

-22°F to 140°F
(-30°C to 60°C)

Resolution

0.2°F (0.1°C)

Main unit batteries

3 x UM-3 (AA) 1.5V

Sensor batteries

2 x UM-4 (AAA) 1.5V

NOTE It is recommended that you use alkaline batteries
with this product for longer performance.

POWER

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products such as digital cameras;
MP3 players; children’s electronic learning products and
games; projection clocks; health and fitness gear; weather
stations; and digital and conference phones. The website
also includes contact information for our Customer Care
department in case you need to reach us, as well as
frequently asked questions and customer downloads.

Calendar

MM / DD; weekday in
5 languages (E, D, F, I, S)

Alarm

Single alarm with
2-minute crescendo and
8-minute snooze

FCC STATEMENT

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.

WARNING Changes or modifications not expressly
approved by the party responsible for compliance could void
the user's authority to operate the equipment.

NOTE This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation.

This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and
receiver.

Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician
for help.

The following information is not to be used as contact for
support or sales. Please call our customer service number
(listed on our website at www.oregonscientific.com), or on
the warranty card for this product) for all inquiries instead.

We

Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Ave.,
Tualatin, Oregon 97062 USA

Telephone No.:

1-800-853-8883

Fax No.:

1-503-684-3332

DECLARATION OF CONFORMITY

declare that the product

Product No.:

BAR636A

Product Name:

Weather Station

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: 1) This device
may not cause harmful interference. 2) This device must
accept any interference received, including interference
that may cause undesired operation.

© 2005 Oregon Scientific. All rights reserved.

P/N.: 086-004021-012

• Remove the batteries if storing this product for a long

period of time.

• Do not scratch the LCD display.

NOTE The technical specification of this product and
contents of this user guide are subject to change without
notice. Images not drawn to scale.

We hope you will find all the information you need on our website,
however if you’re in the US and would like to contact the Oregon
Scientific Customer Care department directly, please visit:
www2.oregonscientific.com/service/support

OR

Call 1-800-853-8883.

For international inquiries, please visit:
www2.oregonscientific.com/about/international

BAR636A_M_EN_V2.p65

2005.7.1, 9:44 AM

2