Operator maintenance, Adjust thermocouple offset, “adj/hold” button – Omega Speaker Systems HH801A User Manual

Page 2: “apo/type” button, “max min” button, “clr/read” button, “rec” button, “t1 t2/t1-t2/ ” button, Warning, Battery replacement

background image

4. “ADJ/HOLD” Button

Press the “HOLD” button to enter the Data Hold mode,
the “HOLD” annunciator is displayed at the top of the
display.
When HOLD mode is selected, the thermometer holds
the present readings and stops all further measurements.
Pressing the “HOLD” button again cancels HOLD mode,
causing the thermometer to resume measurement.

5. “APO/TYPE” Button

Press “TYPE” button to select the type of thermocouple
“K” or “J”. Make sure the proper type has been selected.
Pressing and holding down “APO” button for 2 seconds
will turn on or off the APO(Automatic Power Off) mode,
and the APO annunciator will appear or disappear on the
display. Power is automatically turned off if no button is
pressed for a period of time.

6. “MAX MIN” Button

Press “MAX MIN” button to enter the MAX MIN re-
cording mode. Press “MAX MIN” button to cycle
through the MAX, MIN, MAX-MIN readings. In this
mode, press “HOLD” button to stop recording, all values
are held, press again to resume measurement. In this
mode, the APO function and other buttons are disabled,
excluding “HOLD” and “ ” buttons.
To prevent accidental loss of MAX, MIN and MAX-MIN,
this mode can only be cancelled by pressing and holding
down the “MAX MIN” button for 2 seconds to exit and
clear readings.

7. “CLR/READ” Button

Press “READ” button to enter READ Mode, the “READ”
annunciator is displayed in the upper right corner. Press
“ ”or “ ” button to review the recorded data. The LCD
automatically alternates between the data and index.
Press the “CLR” button and hold down for 2 seconds to
clear the memory data.

8. “REC” Button

Up 125 data points can be recorded into memory.
Press “REC” button once to record each data point. When
the data is recorded, “REC” is displayed in the upper
right corner. If the memory is full, data will not be re-
corded into the memory and “REC” will not be displayed.
Data can be recorded again after the memory is cleared.

9. “T1 T2/T1-T2/ ” Button

Press “T1”, “T2”, “T1-T2” button to select input mode
T1, T2 or T1-T2. The input selection indicates which
input is selected for display, T1 thermocouple, T2 ther-
mocouple or the differential between the two thermocou-
ples (T1-T2).

ADJUST THERMOCOUPLE OFFSET

1. Insert the thermocouple into a known temperature (T)

until the display stabilizes near the known temperature
(T).
example: ice point at 0°C or boiling water at 100°C

2. Press and hold the “ADJ/HOLD” button for 2 seconds

until the display starts to blink.

3. Press “ ” or “ ” to adjust the displayed value.
4. It can be adjusted ±6°F (±3°C) from default. If you can

not adjust your reading to match the known tempera-
ture (T), please check your T/C type. The meter may
require calibration.

5. Press “ENTER” button to confirm.

OPERATOR MAINTENANCE

WARNING

To avoid possible electrical shock, disconnect the

thermocouple connectors from the thermometer before

removing the cover.

Battery Replacement

1. Power is supplied by 4pcs 1.5V (AAA SIZE) UM-4

R03.

2. The “

” appears on the LCD display when replace-

ment is needed. To replace battery remove screw from
back of meter and lift off the battery cover.

3. Remove the battery from battery contacts and replace.
4. When not in use for long periods remove battery.
5. Do not store in locations with high temperatures, or

high humidity.

Cleaning

Periodically wipe the case with a damp cloth and deter-
gent, do not use abrasives or solvents.

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in

materials and workmanship for a period of 13 months from date of

purchase. OMEGA’s WARRANTY adds an additional one (1) month grace

period to the normal one (1) year product warranty to cover handling

and shipping time. This ensures that OMEGA’s customers receive maximum

coverage on each product.

If the unit malfunctions, it must be returned to the factory for evaluation.

OMEGA’s Customer Service Department will issue an Authorized Return (AR)

number immediately upon phone or written request. Upon examination by

OMEGA, if the unit is found to be defective, it will be repaired or replaced at

no charge. OMEGA’s WARRANTY does not apply to defects resulting from

any action of the purchaser, including but not limited to mishandling,

improper interfacing, operation outside of design limits, improper repair, or

unauthorized modification. This WARRANTY is VOID if the unit shows

evidence of having been tampered with or shows evidence of having been

damaged as a result of excessive corrosion; or current, heat, moisture or

vibration; improper specification; misapplication; misuse or other operating

conditions outside of OMEGA’s control. Components in which wear is not

warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various

products. However, OMEGA neither assumes responsibility for any

omissions or errors nor assumes liability for any damages that

result from the use of its products in accordance with information

provided by OMEGA, either verbal or written. OMEGA warrants

only that the parts manufactured by the company will be as

specified and free of defects. OMEGA MAKES NO OTHER

WARRANTIES OR REPRESENTATIONS OF ANY KIND

WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE,

AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE

ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The

remedies of purchaser set forth herein are exclusive, and the total

liability of OMEGA with respect to this order, whether based on

contract, warranty, negligence, indemnification, strict liability or

otherwise, shall not exceed the purchase price of the component

upon which liability is based. In no event shall OMEGA be liable

for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor

shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in

or with any nuclear installation or activity; or (2) in medical applications or

used on humans. Should any Product(s) be used in or with any nuclear

installation or activity, medical application, used on humans, or misused in

any way, OMEGA assumes no responsibility as set forth in our basic

WARRANTY / DISCLAIMER language, and, additionally, purchaser will

indemnify OMEGA and hold OMEGA harmless from any liability or damage

whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS / INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer

Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,

PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER

FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO

AVOID PROCESSING DELAYS). The assigned AR number should then be

marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and

proper packaging to prevent breakage in transit.

FOR WARRANTY RETURNS, please

have the following information

available BEFORE contacting

OMEGA:

1. Purchase Order number under

which the product was

PURCHASED,

2. Model and serial number of the

product under warranty, and

3. Repair instructions and/or specific

problems relative to the product.

FOR NON-WARRANTY REPAIRS,

consult OMEGA for current repair

charges. Have the following

information available BEFORE

contacting OMEGA:

1. Purchase Order number to cover

the COST of the repair,

2. Model and serial number of the

product, and

3. Repair instructions and/or specific

problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever

an improvement is possible. This affords our customers the latest in

technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This

document may not be copied, photocopied, reproduced, translated, or

reduced to any electronic medium or machine-readable form, in whole or

in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for

Process Measurement and Control?

OMEGA…Of Course!

Shop online at omega.com

TEMPERATURE

Thermocouple, RTD & Thermistor Probes,

Connectors, Panels & Assemblies

Wire: Thermocouple, RTD & Thermistor

Calibrators & Ice Point References

Recorders, Controllers & Process Monitors

Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

Transducers & Strain Gages

Load Cells & Pressure Gages

Displacement Transducers

Instrumentation & Accessories

FLOW/LEVEL

Rotameters, Gas Mass Flowmeters & Flow Computers

Air Velocity Indicators

Turbine/Paddlewheel Systems

Totalizers & Batch Controllers

pH/CONDUCTIVITY

pH Electrodes, Testers & Accessories

Benchtop/Laboratory Meters

Controllers, Calibrators, Simulators & Pumps

Industrial pH & Conductivity Equipment

DATA ACQUISITION

Data Acquisition & Engineering Software

Communications-Based Acquisition Systems

Plug-in Cards for Apple, IBM & Compatibles

Data Logging Systems

Recorders, Printers & Plotters

HEATERS

Heating Cable

Cartridge & Strip Heaters

Immersion & Band Heaters

Flexible Heaters

Laboratory Heaters

ENVIRONMENTAL MONITORING AND CONTROL

Metering & Control Instrumentation

Refractometers

Pumps & Tubing

Air, Soil & Water Monitors

Industrial Water & Wastewater Treatment

pH, Conductivity & Dissolved Oxygen Instruments