Refilling Your Canister Vapor Cleaner With Water

Step 1: Press On/Off Button to turn the unit “Off”. Depress the Vapor Switch only

on the Pistol Grip to “On” and leave “On” for 10 minutes to ensure that
any remaining pressure in the boiler has been released.

Step 2: Depress the Vapor Switch on the Pistol Grip to the “Off” position and

disconnect Electrical Power Cord from wall outlet.

Step 3: Wait an additional 10 minutes before opening the Safety Cap. Carefully

loosen the Safety/Filler Cap by rotating counterclockwise. Any residual
steam will be released below the Safety/Filler Cap if the tank has not
been completely vented. When the hissing stops and the last of the
vapor has been released, remove the filler cap.

Step 4: Allow the vapor cleaner to cool for 5-10 minutes before refilling with

water.

Step 5: Refill water tank with water using the Refill Bottle, as previously described.

Step 6: Firmly screw the Safety Filler Cap back onto the Vapor Cleaner by

turning clockwise and pressing down lightly.

Step 7: Connect power cord to the wall outlet. Press the On/Off Power Switch

and wait until the Temperature Ready Light comes on before you

continue cleaning.

WARNING: If you attempt to refill the machine while the Vapor
Generator is still hot, there is a risk that water will be squirted back
during filling and cause scalding. Extreme care should be taken
when refilling the unit.

Using Your Canister Vapor Cleaner with Floor Brush

Step 1: Connect one of the Extension

Tubes to the Pistol Grip on the
Flexible Vapor Hose. To insert
the Extension Tubes one onto
the other or onto the Pistol Grip,
press the button ensuring that it
fits into the hole. To disconnect,
repeat the operation by pressing
the button and pulling the two
pieces apart.