beautypg.com

Environmental, Operating temperatures, Storage temperature – Oki BISM2 User Manual

Page 28: Reliability

background image

www.ezurio.com

12.4.2 FCC and Industry Canada Statements

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.

12.4.2.1

FCC Labelling requirement

If the FCC ID is not visible when the module is installed inside another device, then the outside of the
device into which the module is installed must also display a label referring to the enclosed module.
This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID:
PI401B” or “Contains FCC ID: PI401B.” Any similar wording that expresses the same meaning may be
used.

13. Environmental

13.1

Operating temperatures

13.2

Storage temperature

13.3

Reliability

Parameter

Test

Comment

Thermal Shock

200 cycles -40ºC /+85ºC 30 min

1 cycle/hour

Vibration

Continuous operation at 60 Hz,
2mm stroke

15g max sine wave, 12 hours

Shock

50G 11ms Half Sine Wave

6 axis x 3 cycles each axis

Moisture Resistance

High Temp Storage

85ºC, 360 hours

Low Temp Storage

-40ºC, 240 hours

High Temp/Humidity
Operation

60ºC, 90%RH, 360 hours

Thermal shock

-40 to 60ºC in 30min

200 cycles with continuous
operation

Electro Static Discharge

EN55024:1998 & IEC61000-4-3

Drop Test

75cm to concrete, 3 axis x 2
cycles per corner

Parameter

Min

Typ

Max

Unit

Operating temp (standard product)

-40

25

+85

°C

Parameter

Min

Max

Unit

Storage temp

-40

+125

°C