How to replace a worn belt, Using a oreck fresh air, Bulb replacement – Oreck SIMPLY AMAZING XL3600HH User Manual
Page 6: Stuffing or blockage
5
E
N
G
L
I
S
H
CAUTION—Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor
Surfaces and Polished Floor Finishes
Use floor and floor finish manufacturer’s recommended methods of
cleaning. The metal strip on the base of the cleaner could be damaged
if used on concrete or abrasive surfaces, and, therefore, cause damage
to wood floors, soft (vinyl, asphalt tile, etc.) floor surfaces and polished
floor finishes. The roller brush may also scuff very soft finishes. Do not
operate the unit while in the upright and locked position. Do not let the
unit run while in any one stationary position for any period of time. Keep
the unit moving while in operation.
Celoc
®
Hypo-Allergenic Filter System
The Celoc SMMS outer bag of your vacuum cleaner is high filtration
medical material designed to filter the smallest of dust particles. It is
important the inside of the outer bag be cleaned. Vacuum the inside of
the outer bag or hand wash, turned inside out, with warm water, and air
dry. For best results, the Celoc SMMS outer bag should be replaced
once a year. The Celoc layered disposable inner dust bag must be
replaced once a month even if it is not full. Change it more often if it is
used in extremely dirty areas. Increase the cleaning power of your
vacuum by changing the bag often.
To Replace Filter Dust Bag
WARNING: Unplug cord from electrical
outlet before servicing.
BAG REMOVAL :
fig. 5
Unzip outer bag completely.
fig. 6
Pull bag cardboard collar to release bag dock door from
connector. Bag dock door will hinge downward.
fig. 7
Gently pull bag cardboard collar upward out of the bag dock.
Dust seal will close automatically.
BAG INSTALLATION :
fig. 8
Slide the cardboard collar completely onto bag dock door.
fig. 9
Firmly push bag dock door with both thumbs on indication point
until it snaps.
How to Replace a Worn Belt
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 10 Remove the replacement belt from the storage channel.
fig. 11 Remove the door by removing the hold down screw located on
side of power head.
fig. 12 Slide the door forward by prying open with a screwdriver or coin.
fig. 13 Remove the belt from the brush roll pulley and motor drive shaft.
fig. 14 Loop the new belt over the motor drive shaft. Place the
opposite end of the belt on the brush roll pulley and roll the belt
around the pulley. Rotate brush roll several times to ensure belt
is tracking on motor pulley.
fig. 12 Replace the door by sliding it into the groove at the bottom of
the housing.
fig. 11 Replace the hold down screw and tighten.
To Adjust or Replace Brush
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 15 To determine if the brush is worn, place a firm straight edge
across the nozzle opening. If brush bristles do not extend
beyond base plate, brush should be adjusted.
fig. 16 Remove the base plate by removing 5 screws.
fig. 17 Remove the belt and brush roll from the housing.
fig. 18 Rotate both bearing assemblies at ends of brush roll to show
"OLD" and replace in the holding channels in the housing.
NOTE: The bearing assembly setting marked "OLD" has no ridges on
the top of the assembly. The one marked "NEW" has several ridges.
When rotating bearings, make sure both bearing assembly settings are
the same and face up when replacing the brush roll.
fig. 15 Reassemble the belt and the base plate and check bristle
height above base plate at each end of brush.
If a previous adjustment has already been made and bristle height does
not extend above base plate, a new brush assembly should be ordered.
IMPORTANT: Unless the brush is worn as indicated above, both
bearings must be in the “NEW” position. When rotating, both
bearings must be in the “OLD” position. Unmatched settings will
cause damage to your machine.
Using A Oreck Fresh Air
®
Tab
fig. 19 Your ORECK XL vacuum cleaner has a special ORECK FRESH
AIR
®
tab pocket. This light-colored pocket is located inside the
vinyl bag in the area where the paper disposable bag attaches
to the intake tube. Insert tablet in pocket if desired.
Bulb Replacement
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 20 Remove lamp housing by removing two (2) screws in the the
top of the lamp housing. Pull burned out bulb from holder and
replace with new bulb. Use only Oreck replacement parts.
Replace lamp housing by replacing two screws in the top of the
lamp housing.
Stuffing or Blockage
IMPORTANT: On plush and new carpets, stuffing may occur inside the
the intake tube and the lower tube assembly. This is due to excessive fuzz
and loose cuttings in the carpet. Stuffing could occur for the first few
cleanings until all the loose material is removed. Due to the high
efficiency of the cleaner, many older carpets will cause stuffing when the
cleaner is first used on them. If your vacuum cleaner does not pick up
properly, or makes unusual noise and the outer bag does not fluff up or
balloon open, follow these steps:
WARNING: Unplug cord from electrical
outlet before servicing.
fig. 21 Check for blockage at the mouth of the intake opening. If there
is blockage, remove it with long-nose pliers, a screwdriver or
coat hanger. If you can not reach the blockage, remove base
plate. (fig. 22)
fig. 23 If the blockage is not at the base, remove lower tube. Unhook
retainer spring, releasing bottom of bag.
fig. 24 Twist lower collar counter clockwise to slide up. Pull tube out of
base.
fig. 25 Check for blockage. If blockage is in the tube, remove with a
coat hanger.
fig. 26 If tube is not blocked, look into fan housing. Remove debris
with long-nose pliers, a screwdriver or coat hanger.
fig. 24 To reassemble, check O-ring on tube, and replace if damaged.
Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place.
fig. 27 Make sure collar is not cross threaded on housing. Reattach
bag spring (fig. 23)
fig. 28 Many times blockage occurs due to a full dust bag causing dirt to
back down the air flow system. When that happens, the
blockage will be at the top of the system, starting in the area
where the dust bag connects to the connector assembly.
NOTE: If the above actions do not correct the problem, contact an
Oreck authorized service center or call the customer service center.
US: 1-800-989-3535 Canada: 1-888-676-7325