1. When the power is down, pressing MEAS button turns on the power.

2. Use "

" button to select turn on or turn off the display Back-Light.

3. Use "

" button to select turn on or turn off the Laser beam.

4. Press the MODE button, if necessary to set the thermal emissivity value (

e

).

5. Point the lens at the object whose temperature is to be measured.
6. Press the MEAS button. Measurement is performed as long as the MEAS

button is kept pressed.

7. Referring to the spot size figure, aim the laser beam at the object whose

temperature is to be measured.
NOTE: Although the field of measurement (or Field of View) and the spot

almost coincide, actually the field of measurement corresponds to the
diameter for 90% optical response. The object whose temperature is
to be measured needs to be larger than the measurement diameter
(spot of size) by an adequate margin at least 1.5 to 2 times larger.

8. Read the display.