Approved standard ratings, Characteristics, D4bl – Omron D4BL User Manual
Page 3: A300, A-69
Guard Lock Safety-door Switch
D4BL
A-69
D4
BL
Sa
fe
ty
Do
or
Sw
it
c
h
e
s
■ Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Use a 10-A fuse type
gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
■ Characteristics
Note: 1. The above values are initial values.
2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water
penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise
Switch damage or malfunctioning may occur.
3. The durability is for an ambient temperature of 5
°C to 35°C and an ambient humidity of 40% to 70%.
4. These figures are minimum requirements for safe operation.
Item
Standard model
Indicator model
Utilization category
AC-15
AC-15
Rated operating current (I
e
)
3 A
6 A
Rated operating voltage (U
e
)
250 V
115 V
Rated voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
10 A
60 A
6 A
7,200 VA
720 VA
240 VAC
30 A
3 A
Degree of protection (See note 2.)
IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is
IP00.)
Durability (See note 3.)
Mechanical: 1,000,000 operations min.
Electrical:
500,000 operations min. (10-A resistive load at 250 VAC)
Operating speed
0.05 to 0.5 m/s
Operating frequency
30 operations/min max.
Rated frequency
50/60 Hz
Contact gap
2 x 2 mm min.
Operating characteristics
Direct opening force: 19.61 N min. (EN60947-5-1) (See note 4.)
Direct opening travel: 20 mm min. (EN60947-5-1) (See note 4.)
All stroke:
23 mm min.
Lock holding strength
700 N min. (GS-ET-19)
Insulation resistance
100 M
Ω min. (at 500 VDC)
Rated insulation voltage (U
i
)
300 V (EN60947-5-1)
Conventional enclosed thermal current
(I
the
)
10 A (EN60947-5-1)
Dielectric strength (U
imp
)
Impulse dielectric strength (U
imp
) 4 kV (EN60947-5-1) between terminals of different polarity, between
each terminal and ground, and between each terminal and non-current-carrying metal part;
2.5 kV between solenoid and ground (EN60947-5-1)
Conditional short-circuit current
100 A (EN60947-5-1)
Pollution degree (operating
environment)
3 (EN60947-5-1)
Protection against electric shock
Class I (with ground terminal)
Switching overvoltage
1,500 V max. (EN60947-5-1)
Contact resistance
50 m
Ω max. (initial value)
Vibration resistance
Malfunction: 10 to 55 Hz, 0.35-mm single amplitude
Shock resistance
Destruction: 1,000 m/s
2
min. (IEC68-2-27)
Malfunction: 300 m/s
2
min. (IEC68-2-27)
Ambient temperature
Operating: –10
°C to 55°C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 800 g