beautypg.com

Approved standard ratings, Characteristics, D4bl – Omron D4BL User Manual

Page 3: A300, A-69

background image

Guard Lock Safety-door Switch

D4BL

A-69

D4
BL

Sa
fe

ty

Do

or

Sw

it

c

h

e

s

Approved Standard Ratings

TÜV (EN60947-5-1), CCC (GB14048.5)

Use a 10-A fuse type

gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.

Characteristics

Note: 1. The above values are initial values.

2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are

sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water
penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise
Switch damage or malfunctioning may occur.

3. The durability is for an ambient temperature of 5

°C to 35°C and an ambient humidity of 40% to 70%.

4. These figures are minimum requirements for safe operation.

Item

Standard model

Indicator model

Utilization category

AC-15

AC-15

Rated operating current (I

e

)

3 A

6 A

Rated operating voltage (U

e

)

250 V

115 V

Rated voltage

Carry current

Current

Volt-amperes

Make

Break

Make

Break

120 VAC

10 A

60 A

6 A

7,200 VA

720 VA

240 VAC

30 A

3 A

Degree of protection (See note 2.)

IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is
IP00.)

Durability (See note 3.)

Mechanical: 1,000,000 operations min.
Electrical:

500,000 operations min. (10-A resistive load at 250 VAC)

Operating speed

0.05 to 0.5 m/s

Operating frequency

30 operations/min max.

Rated frequency

50/60 Hz

Contact gap

2 x 2 mm min.

Operating characteristics

Direct opening force: 19.61 N min. (EN60947-5-1) (See note 4.)
Direct opening travel: 20 mm min. (EN60947-5-1) (See note 4.)
All stroke:

23 mm min.

Lock holding strength

700 N min. (GS-ET-19)

Insulation resistance

100 M

Ω min. (at 500 VDC)

Rated insulation voltage (U

i

)

300 V (EN60947-5-1)

Conventional enclosed thermal current
(I

the

)

10 A (EN60947-5-1)

Dielectric strength (U

imp

)

Impulse dielectric strength (U

imp

) 4 kV (EN60947-5-1) between terminals of different polarity, between

each terminal and ground, and between each terminal and non-current-carrying metal part;
2.5 kV between solenoid and ground (EN60947-5-1)

Conditional short-circuit current

100 A (EN60947-5-1)

Pollution degree (operating
environment)

3 (EN60947-5-1)

Protection against electric shock

Class I (with ground terminal)

Switching overvoltage

1,500 V max. (EN60947-5-1)

Contact resistance

50 m

Ω max. (initial value)

Vibration resistance

Malfunction: 10 to 55 Hz, 0.35-mm single amplitude

Shock resistance

Destruction: 1,000 m/s

2

min. (IEC68-2-27)

Malfunction: 300 m/s

2

min. (IEC68-2-27)

Ambient temperature

Operating: –10

°C to 55°C (with no icing)

Ambient humidity

Operating: 95% max.

Weight

Approx. 800 g