Operating Parameters

Section 2. - Operating Parameters

A. Temperature

Since the FTB600B Series has printed circuit boards molded into the
body of the meter it is strongly recommended that 180°F not be
exceeded. Exceeding 180°F can cause irreparable damage to the circuit
boards.

B. Flow Ranges

The FTB600B Series is available in six different sizes, which cover a
flow range from 0.1 to 120 lpm.
Specific flow ranges
FTB601B

0.1 to 2 lpm

(0.03 to 0.53 gpm)

FTB602B

0.3 to 9 lpm

(0.08 to 2.38 gpm)

FTB603B

0.5 to 15 lpm

(0.13 to 3.96 gpm)

FTB604B

1.0 to 30 lpm

(0.26 to 7.93 gpm)

FTB605B

2.5 to 75 lpm

(0.66 to 19.8 gpm)

FTB606B

4.0 to 120 lpm

(1.32 to 32 gpm)

Over range may permanently damage the flow meter.