beautypg.com

Chapter 7 program examples – Omega Speaker Systems VR200 User Manual

Page 36

background image

7 - 1

7 PROGRAM EXAMPLES

Chapter 7 PROGRAM EXAMPLES

Examples of application programs for an IBM PC are shown below.

Environment

Computer used: IBM PC
Mode:

Character length = 8 bits, parity = none, stop bit = 1, baud rate =
1200 bps

Handshake:

None

The file name used for writing to and reading from the floppy disk is TEST.DAT.

7.1 Program to Read Parameter Settings from VR200, Display Them

on Screen and Write Them to Disk

100

‘************************************************************

110

‘** RS422A Example Program for IBM PC **

120

‘** **

130

‘** To input and save parameter settings **

140

‘** **

150

‘************************************************************

160

‘**

170

‘** Baud rate: 1200 Stop bit: 1 bit

180

‘** Parity: none Control: OFF/OFF

190

‘** Data length: 8 bits

Others: LF is sent automatically.

200

‘**

210

220

OPEN “COM1:1200,N,8,1,LF” AS #1

230

OPEN “TEST.DAT” FOR OUTPUT AS #2

240

250

LF$=CHR$(&HA)

:’ Line feed = 0AH

260

PRINT #1,CHR$(27)+”O 01"

270

PRINT #1,”TS1"

280

PRINT #1,CHR$(27)+”T”;

290

PRINT #1,”LF01,04"

300

LINE INPUT #1,D$

310

IF LEFT$(D$,1)=LF$ THEN D$=MID$(D$,2) :’ Remove “LF” of head string

320

PRINT D$

330

PRINT #2,D$

340

IF LEFT$(D$,2)<>”EN” THEN GOTO 300

350

360

PRINT #1,CHR$(27)+”C 01"

370

CLOSE

380

END

7.1 Program to Read Parameter Setting from VR200, Display Them on Screen and Write Them to Disk