6.11. Customization of Demo Program Settings

The following definitions can be changed at the top of the ZDK_Demo.c file to fit your requirements.

/* ZigBee Configuration */

#define

DEMO_CHANNEL 1

#define

SCAN_CHANNELS ((DWORD)0x1 << DEMO_CHANNEL)

/* Only scan our demo

channel */

//#define SCAN_CHANNELS 0x7FFF800 /* Scan every channel */

ZbPANId s_LocalPanId = 0x1ACE;

/* MUST BE A VALUE LOWER THAN 0x3FFF */

/* ASCII Input */

#define

MAX_SERIAL_INPUT 20

/* Address Book */

// This array holds the addresses of all the nodes currently

// on the network. It is updated only by the coordinator.

#define

MAX_BOOK_ENTRIES 32

/* RECEIVE BUFFER */

#define

RX_BUFF_SIZE 256

/* Circular buffer size for data payload (all

data is held in this one buffer) */

#define

RX_BUFF_ENTRIES 16

/* Number of buffered packet that can be

queued up */

6.12. Other Limitations

The RZB-ZMD16C-ZDK provides sophisticated debugging features at a low cost, but it does have some
limitations when used with the HEW software debugger and ICD. Those limitations are described in more
detail in the RZB-ZMD16C-ZDK User manual (Start > (All) Programs > Renesas > RZB_ZMD16C_ZDK >
All Manuals and Documents).

RZB-ZMD16C-ZDK User’s Manual Rev 1.2 16/ 33