beautypg.com

Maintenance, Fan maintenance – Regency IG34-LPG User Manual

Page 26

background image

26

Regency IG34 Gas Inbuilt Fireplace

MAINTENANCE

FAN MAINTENANCE

To Remove Fan:

1) Turn the unit off and allow it to cool to room temperature,

2) Unplug or disconnect power source to stove.

3) Open the bottom louvre.

4) Remove screws that secure protective screen.

5) Remove door frame and screen

6) Remove the ECS harness from the back clip.

7) Pull out the ECS box.

NOTE: The ECS box is held in place with velcro.

8) Remove the 2 screws that secure the fan in place.


9) Carefully slide the fan to the front, rotate it 45 degrees and slide it out simultaneously with the ECS box.

10) Disconnect all the connectors from the fan and resistor.

11) Remove the fan ground cable.

12) Reverse the above steps to install the new fan.

Fan Ground

Cable

Fan

Connectors

Resistor

Connectors

This manual is related to the following products: