Regency U41-3 ULTIMATE Gas Fireplace Insert

This is a copy of the label that accompanies
each Regency ULTIMATE Gas Insert. We
have printed a copy of the contents here
for your review. The safety label is located
on the right side door panel.

NOTE: Regency units are constantly being
improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.

SAFETY LABEL

DO NOT REMOVE THIS LABEL

Duplicate
Serial No.

225

Serial No.

225

Listed:
Certified:
Tested to:

Report No.

Vented Gas Fireplace Heater
For Canada & USA
CAN/CGA 2.17-M91,
ANSI Z21.88b-2003/CSA 2.33b-2003
476-1042 & 476-1752 (Jan. 2000)

NATURAL GAS FIREPLACE INSERT

Model U41-NG3:

Altitude 0-2000 ft (0-610 m)

Min. Supply Pressure

5"

WC/C.E. (1.25kPa)

Manifold Pressure High 3.8"

WC/C.E. (0.94kPa)

Manifold Pressure Low 1.1"

WC/C.E. (0.27kPa)

Orifice Size

#32

DMS

Altitude

0-2000 ft/pi

(0-610m)

Maximum Input

38,000 Btu/h

(11.14Kwh)

Minimum Input

20,000 Btuh

(5.86Kwh)

NATURAL GAS FIREPLACE INSERT

Model U41-NG3:

Field Convertible for Altitude

2000-4500 ft (610-1370 m). Use Kit #610-975

(Report No. 476-1299)

Min. Supply Pressure

5"

WC/C.E. (1.25kPa)

Manifold Pressure High 3.8“

WC/C.E. (0.94kPa)

Manifold Pressure Low 1.1"

WC/C.E. (0.27kPa)

Orifice Size

#33

DMS

Altitude

2000-4500 ft/pi (610-1370m)

Maximum Input

34,000 Btu/h

(9.96Kwh)

Minimum Input

18,000 Btu/h

(5.28kwh)

This appliance must be installed in accordance

with local codes, if any; if not, follow current

ANSI Z223.1 / CAN/CGA-B149. This vented gas

fireplace heater is not for use with air filters. For

direct discharge without duct connections.

Electrical Supply

115V,1.13A, 60Hz.

This fireplace has

been converted for use with a gas fireplace insert

only and cannot be used for burning wood or

solid fuels unless all original parts have been replaced

and the fireplace re-approved by the authority

having jurisdiction.

:

NOT

FOR USE WITH SOLID FUEL.

WARNING

MINIMUM CLEARANCES TO

COMBUSTIBLES: FROM HEATER

Side Wall:

A

7.5"

(190mm)

Ceiling:

B

35"

(890mm)

Mantel:

C

11"

(280mm)

Mantel Width:

G

5.5"

(140mm)

Alcove Width:

K

48"

(1120mm)

Max.Alcove Depth

M

36"

(915mm)

G

H

K

B

C

A

J

L

M

NON-COMBUSTIBLE HEARTH EXTENSION

Hearth Height

Hearth Depth

(H)

(L)

Option #1:

4.0" (100mm)

16" (405mm)

Option #2:

0.5" (15mm)

24" (610mm)

Hearth Width

(J) 40"(1015mm)

FPI Fireplace Products International Ltd.

Delta, B.C.

918-467

Made in CANADA

PROPANE GAS

0-2000 ft (0-610 m) ONLY

Model U41-LP3:

Min. Supply Pressure

12"

WC/C.E. (3.00kPa)

Manifold Pressure High 11"

WC/C.E. (2.74kPa)

Manifold Pressure Low 2.9"

WC/C.E. (0.72kPa)

Orifice Size

#50

DMS

Altitude

0-2000 ft/pi

(0-610m)

Maximum Input

38,000 Btu/h

(11.14Kwh)

Minimum Input

20,000 Btu/h

(5.86Kwh)

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.