Safety label – Regency Wraps U41-NG3 User Manual
Page 4
4
Regency U41-3 ULTIMATE Gas Fireplace Insert
This is a copy of the label that accompanies
each Regency ULTIMATE Gas Insert. We
have printed a copy of the contents here
for your review. The safety label is located
on the right side door panel.
NOTE: Regency units are constantly being
improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.
SAFETY LABEL
DO NOT REMOVE THIS LABEL
Duplicate
Serial No.
225
Serial No.
225
Listed:
Certified:
Tested to:
Report No.
Vented Gas Fireplace Heater
For Canada & USA
CAN/CGA 2.17-M91,
ANSI Z21.88b-2003/CSA 2.33b-2003
476-1042 & 476-1752 (Jan. 2000)
NATURAL GAS FIREPLACE INSERT
Model U41-NG3:
Altitude 0-2000 ft (0-610 m)
Min. Supply Pressure
5"
WC/C.E. (1.25kPa)
Manifold Pressure High 3.8"
WC/C.E. (0.94kPa)
Manifold Pressure Low 1.1"
WC/C.E. (0.27kPa)
Orifice Size
#32
DMS
Altitude
0-2000 ft/pi
(0-610m)
Maximum Input
38,000 Btu/h
(11.14Kwh)
Minimum Input
20,000 Btuh
(5.86Kwh)
NATURAL GAS FIREPLACE INSERT
Model U41-NG3:
Field Convertible for Altitude
2000-4500 ft (610-1370 m). Use Kit #610-975
(Report No. 476-1299)
Min. Supply Pressure
5"
WC/C.E. (1.25kPa)
Manifold Pressure High 3.8“
WC/C.E. (0.94kPa)
Manifold Pressure Low 1.1"
WC/C.E. (0.27kPa)
Orifice Size
#33
DMS
Altitude
2000-4500 ft/pi (610-1370m)
Maximum Input
34,000 Btu/h
(9.96Kwh)
Minimum Input
18,000 Btu/h
(5.28kwh)
This appliance must be installed in accordance
with local codes, if any; if not, follow current
ANSI Z223.1 / CAN/CGA-B149. This vented gas
fireplace heater is not for use with air filters. For
direct discharge without duct connections.
Electrical Supply
115V,1.13A, 60Hz.
This fireplace has
been converted for use with a gas fireplace insert
only and cannot be used for burning wood or
solid fuels unless all original parts have been replaced
and the fireplace re-approved by the authority
having jurisdiction.
:
NOT
FOR USE WITH SOLID FUEL.
WARNING
MINIMUM CLEARANCES TO
COMBUSTIBLES: FROM HEATER
Side Wall:
A
7.5"
(190mm)
Ceiling:
B
35"
(890mm)
Mantel:
C
11"
(280mm)
Mantel Width:
G
5.5"
(140mm)
Alcove Width:
K
48"
(1120mm)
Max.Alcove Depth
M
36"
(915mm)
G
H
K
B
C
A
J
L
M
NON-COMBUSTIBLE HEARTH EXTENSION
Hearth Height
Hearth Depth
(H)
(L)
Option #1:
4.0" (100mm)
16" (405mm)
Option #2:
0.5" (15mm)
24" (610mm)
Hearth Width
(J) 40"(1015mm)
FPI Fireplace Products International Ltd.
Delta, B.C.
918-467
Made in CANADA
PROPANE GAS
0-2000 ft (0-610 m) ONLY
Model U41-LP3:
Min. Supply Pressure
12"
WC/C.E. (3.00kPa)
Manifold Pressure High 11"
WC/C.E. (2.74kPa)
Manifold Pressure Low 2.9"
WC/C.E. (0.72kPa)
Orifice Size
#50
DMS
Altitude
0-2000 ft/pi
(0-610m)
Maximum Input
38,000 Btu/h
(11.14Kwh)
Minimum Input
20,000 Btu/h
(5.86Kwh)
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.