Electrical connection

Your washing machine is set to 220-240V and 50Hz.

Mains cord of your washing machine is equipped with a specific
grounded plug. This plug should always be inserted to a grounded
receptacle of 10 amps. Fuse current value of the power line
connected to this plug should also be 10 amps.

If you don‟t have

such a receptacle and fuse confirming with this, please have it
done by a qualified electrician.

We do not take responsibility for the damages that occur due

to ungrounded usage.

Operating your machine under low voltage will cause the life cycle

of your machine to be reduced and its performance to be
restricted.


Water inlet connection

Your machine has a single water (cold) inlet.

To prevent leakages on the connection joints, 1 seal is included in

the hose packing, (Fit this seal on the end of the water inlet hose at
the tap side.)

Connect the bracketed end of the water inlet hose to the water inlet

valve at the rear of the machine and the other end to your tap. In
situations where you are not sure, let a qualified plumber perform
the connection process.

Water pressure of 0,1-1 MPa from your tap will enable your

machine to work more efficiently, (0,1 MPa pressure means water
flow of more than 8 litres in 1 minute from a fully opened tap).

After all connections are completed, check for leakages around the

connection joints by turning on your tap completely and seeing if
any water escapes.

Be sure that water inlet hoses are not folded, broken or crushed.

Mount

the water inlet hoses to a 3”/4 geared water tap.