Sampling Frequency settings
Set the sampling frequency of the VS-2400CD and ADAT device to the same setting (48 kHz).
■
Master Clock settings
You'll also need to set the Master Clock for the ADAT device. For details on this setting, refer to the owner's
manual for the ADAT device.
■
Synchronization settings
Set the VS-2400CD's parameters as follows.
MIDI PARAMETER screen
❍ SysEx. Rx. Sw. On
❍ MMC MODE.. SLAVE
❍ MMC SOURCER-BUS
SYNC PARAMETER screen
❍ SYNC MODE . EXT
❍ EXT SYNC SOURCER-BUS
❍ FRAME RATE..................... Same setting as the software.*
■
BRC settings
1
Press [EDIT]
➔
[GEN SYNC]
➔
[GEN SYNC].
The screen will indicate “Generate Sync.”
2
Use [
▲
][
▼
] to select “MIDI: MTC,” and press [EDIT].
[EDIT] will go dark.
3
Press [GEN SYNC].
[GEN SYNC] will light, and the BRC will output MTC.
Master clock device
VS-2400CD setting
DIF-AT24
MASTER CLK switch
VS-2400CD
PROJECT PARAMETER screen
❍ MASTER CLOCL................INT
R-BUS
ADAT device
PROJECT PARAMETER screen
❍ MASTER CLOCL................R-BUS
ADAT