Rhfe-750etra, Wd h – Rinnai RHFE-750ETRA User Manual
Page 2
![background image](/manuals/201154/2/background.png)
RHFE-750ETRA
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
LOCATION
Description Part
Number
Flat Metal - Black Front
R2700
Flat Metal - Stainless Steel Front
R2701
Radius Glass - Silver Front
R2702
Radius Glass - Black Front
R2703
Available Fascias (Front Panels)
Wall penetration hole: 3 1/2 in (90 mm)
Minimum Enclosure Dimensions in
a Corner
x
63.8 in (1620 mm)
y
45.1 in (1146 mm)
z
31.9 in (810 mm)
w
d
h
x
y
z
Width (w)
33.8 in (860 mm)
Height (h)
26.0 - 26.2 in (660-665 mm)
Depth (d)
15.0 - 16.9 in (380-430 mm)
Minimum Enclosure Dimensions
FOT-203 /
FOT-204
Name Kit
No. fits
walls
Vent Kit A
FOT-203
4 1/3 - 9 1/2 inch
(110 - 240 mm)
Vent Kit B
FOT-204
9 1/2 - 15 3/4 inch
(240 - 400 mm)
The FOT-203 Vent Kit is included with the appliance.
Flue extensions are not authorized to be used with
the FOT-203 and FOT-204 manifolds.
VENTING WITH NO EXTENSIONS
FASCIAS
Clearances for a mantle or
decorative overhang
5”
45
3” Minimum
Interior
wall
1”
2”
3”
4”
Side view