beautypg.com

8035c features – ritetemp 8035C User Manual

Page 9

background image

PG

16

PG

15

STEP 1 - Connect the G

wire to the G terminal on the

thermostat.

This connects the Fan.

STEP 2 - Add a jumper wire

between W and Y.

STEP 3 - Connect the Y wire

to the Y terminal on the

thermostat.

This connects the Compressor.

STEP 4 - Connect the O or B wire to the O or B

terminal on the thermostat. (If you have both O

and B contact Ritetemp or your local HVAC

contractor for further help) This connects the change over valve.

STEP 5 - Connect the R wire to the RC terminal on the Thermostat.

This connects to the 24vac power.

Your HVAC system is now connected to the thermostat.

Return To Page 9

NOTE: Wires marked with the

dotted line are optional.

From Furnace
and AC unit

R

G

Y

C

O

or

B

The 8035C can be used with most 24 volt gas, oil or electric heating and air conditioning systems,
single-stage heat pumps or gas millivolt heating systems. It cannot be used with 120 volt heating
systems or multistage heat pumps. Ask The Home Depot for other thermostats to control those
systems.

The 8035C is programmable. There are four programming

periods per day. Each period can be programmed

separately.

You can use the built-in time/temperature programs, or alter

them to suit your schedule.

The 8035C separately programs each weekday, Saturday,

and Sunday - for both heating and cooling.

You can easily override the programmed temperatures for as

little as one programming period or for an entire vacation.

The large liquid crystal touch screen display shows time, day

of the week, room and set temperatures. It will also remind

you when the filter should be changed in your blower.

Temperature swing adjustment lets you fine-tune your system for maximum comfort and
energy efficiency.

A 4-minute minimum off time in COOL protects your air conditioning system from being
damaged.

Two "AA" batteries (included) are used to retain your time and temperature programs, and to

8035C Features

HEAT PUMP

without auxiliary heat

O or B

Single Stage HEAT PUMP

Change
Over

G

O or B

R

C

FAN

Y

Comp

24VAC

Power

jumper
wire

jumper
wire

Thermostat

A

RESET

MENU

PROG