8035c features – ritetemp 8035C User Manual
Page 9
PG
16
PG
15
STEP 1 - Connect the G
wire to the G terminal on the
thermostat.
This connects the Fan.
STEP 2 - Add a jumper wire
between W and Y.
STEP 3 - Connect the Y wire
to the Y terminal on the
thermostat.
This connects the Compressor.
STEP 4 - Connect the O or B wire to the O or B
terminal on the thermostat. (If you have both O
and B contact Ritetemp or your local HVAC
contractor for further help) This connects the change over valve.
STEP 5 - Connect the R wire to the RC terminal on the Thermostat.
This connects to the 24vac power.
Your HVAC system is now connected to the thermostat.
Return To Page 9
NOTE: Wires marked with the
dotted line are optional.
From Furnace
and AC unit
R
G
Y
C
O
or
B
The 8035C can be used with most 24 volt gas, oil or electric heating and air conditioning systems,
single-stage heat pumps or gas millivolt heating systems. It cannot be used with 120 volt heating
systems or multistage heat pumps. Ask The Home Depot for other thermostats to control those
systems.
The 8035C is programmable. There are four programming
periods per day. Each period can be programmed
separately.
You can use the built-in time/temperature programs, or alter
them to suit your schedule.
The 8035C separately programs each weekday, Saturday,
and Sunday - for both heating and cooling.
You can easily override the programmed temperatures for as
little as one programming period or for an entire vacation.
The large liquid crystal touch screen display shows time, day
of the week, room and set temperatures. It will also remind
you when the filter should be changed in your blower.
Temperature swing adjustment lets you fine-tune your system for maximum comfort and
energy efficiency.
A 4-minute minimum off time in COOL protects your air conditioning system from being
damaged.
Two "AA" batteries (included) are used to retain your time and temperature programs, and to
8035C Features
HEAT PUMP
without auxiliary heat
O or B
Single Stage HEAT PUMP
Change
Over
G
O or B
R
C
FAN
Y
Comp
24VAC
Power
jumper
wire
jumper
wire
Thermostat
A
RESET
MENU
PROG