Technical data, This cooker is designed for use on either, Dimensions – Rangemaster 90 Gas User Manual
Page 37: Connections, Ratings, Hotplate, Main oven, Grill, Tall oven

37
Technical Data
This cooker is designed for use on either :-
NATURAL GAS (Cat I2H ) at 20mbar or
LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.
NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT
MODELS AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB
Gas
Electric
Natural Gas
20mbar
220 - 240V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height including optional splashback
minimum 1060mm
maximum 1090mm
Overall height
minimum 893mm
maximum 920mm
Overall width
900mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp
1
/
2
at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Hotplate
Injector
Injector
Wok burner
3.5kW
internal 80
3.5kW (246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners
1.7kW
109
1.7kW (119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Main Oven
3.2kW
237
2.9kW (224g/h)
85
Grill
2.73kW
190
2.73kW (192g/h)
85
Gas burner inputs based on Gross Calorifi c Value
Tall Oven
Forced air convection
2.5kW
Energy effi ciency class on a scale of A (more effi cient) to G (less effi cient)
B
Energy consumption based on standard load
0.95kWh
Usable volume (litres)
53
Size
Medium
Maximum total electrical load at 230V 2.6kW (approximate total including oven light, oven fan etc.)