beautypg.com

Safety label, Do not remove this label, Minimum clearances to combustibles – Regency C33-LP2 User Manual

Page 5

background image

Regency CLASSIC C33-2 Freestanding Gas Stove

5

SAFETY LABEL

This is a copy of the label that accompanies each
CLASSIC Freestanding Gas Stove - Propane.
We have printed a copy of the contents here for
your review. The safety label is located on the
back panel.

NOTE: Regency units are constantly being im-
proved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.

Minimum supply pressure 12"

WC/C.E.(2.85Kpa)

Manifold pressure High

11"

WC/C.E.(2.61Kpa)

Manifold pressure Low

2.9"

WC/C.E.(0.72Kpa)

Orifice size

52

DMS

Altitude

0-2000 ft/pi

(0-610 m)

Maximum Input

33,000 BTUH

(9.67Kw/h)

Minimum Input

17,000 BTUH

(4.98Kw/h)

FACTORY EQUIPPED FOR PROPANE:

Model C33-LP2

GAS FIRED VENTED ROOM HEATER

This appliance must be installed in accordance

with local codes, if any; If not, follow:

ANSI Z223.1/CAN 1-B149.

Electrical Supply (115 V, 1.13 A, 60 Hz)

Not for use with solid fuel.

Optional Fan: (Part #490-917)

Listed

Certified for:

Report No.

Tested to:

: GAS FIRED VENTED ROOM HEATER

CANADA and USA

476-1345-00 (Oct. 1996)

ANSI Z21.88b-2003/CSA 2.33b-2003

FPI Fireplace Products International Ltd.

Delta, BC, Canada

Serial No.

200

Made in Canada

908-635a

DO NOT REMOVE THIS LABEL

Minimum Clearances to Combustibles

Minimum ceiling height from top of unit: 36"/914mm

Back wall

Side

wall

E

A - 10"

E - 1.5"

A

A

B

Back wall

Side

wall

Side

wall

B - 6"