beautypg.com

Wiring diagrams, Cool only 3-wire single transformer, Heat/cool 5-wire two transformer – Robertshaw 8600 User Manual

Page 5: Heat pump with cool active reversing valve, Heat pump with heat active reversing valve

background image

Wiring Diagrams

The following is just a sample of the most common types of HVAC
systems. Refer to your system’s installation manual for wiring information.

5

Hot

Heating
Control

Fan

Control

Cooling

Control

Heating
Control

(COOLING)

Transformer

(HEATING)

Transformer

Transformer

T

H
E
R

M
O

S
T
A
T

RH

RC

W1

Y1

G

O

B

24 VAC

120 VAC

Hot

Heating
Control

Fan

Control

Transformer

24 VAC

120 VAC

Hot

Heating
Control

Transformer

24 VAC

120 VAC

Hot

120 VAC

24 VAC

24 VAC

Hot

120 VAC

HEAT/COOL

4-WIRE

SINGLE TRANSFORMER

HEAT ONLY

2-WIRE

SINGLE TRANSFORMER

HEAT ONLY

SINGLE TRANSFORMER

3-WIRE

Factory-Installed

Jumper

Hot

Cooling

Control

Fan

Control

Transformer

24 VAC

120 VAC

COOL ONLY

3-WIRE

SINGLE TRANSFORMER

Cooling

Control

HEAT/COOL

5-WIRE

TWO TRANSFORMER

RH

RC

W1

Y1

G

Factory-Installed

Jumper

RH

RC

W1

Y1

G

NOTE: Disconnect
factory installed jumper.

RH

RC

W1

Y1

G

Hot

Compressor

Contactor

Transformer

24 VAC

120 VAC

HEAT PUMP WITH

COOL ACTIVE

REVERSING VALVE

RH

RC

W1

Y1

B

G

O

RC

RH

W1

Y1

G

CAUTION: Both transformers
must be in phase or damage

may result.

to the equipment and thermostat

Hot

Transformer

24 VAC

120 VAC

HEAT PUMP WITH

HEAT ACTIVE

REVERSING VALVE

RH

RC

W1

NOTE: Factory
Installed Jumper

NOTE: Factory
Installed Jumper

T

H
E
R

M
O

S
T
A
T

T

H
E
R

M
O

S
T
A
T

T

H
E
R

M
O

S
T
A
T

T

H
E
R

M
O

S
T
A
T

T

H
E
R

M
O

S
T
A
T

T

H
E
R

M
O

S
T
A
T

NOTE: Remove factory
installed jumper

NOTE: Make sure the HP switch

is in the HP position

NOTE: Make sure the HP switch

is in the HP position

O

B

O

B

O

B

O

B

Fan

Relay

Reversing

Valve

Fan

Relay

Compressor

Contactor

Y1

G

O

B

Reversing

Valve

Fan

Relay